SYMPTOM
G. MOTOR OVERHEATS
Application
Pump Housing
Performance:
Pump Rate
Duty Cycle
Suction Lift:
Discharge Lift:
Operating Temperature
XTS Operating Temperature
Bypass Pressure
Electrical Specifications:
Input
Current Draw
Motor
Motor Approval
Motor Protection
Cord*
Fuse
Mechanical Connection:
Bung
Inlet
Outlet
Accessories:
Hose Type
Hose Size
Manual Nozzle
Automatic Nozzle
Weight:
PRO25-012PO
PRO25-024PO
6
TROUBLESHOOTING
PROBABLE CAUSE
1. Pumping high viscosity fluids
2. Clogged filter assembly
3. Clogged or broken suction pipe Remove pump and clear suction pipe, replace as needed.
4. Duty cycle too long
5. Motor failure
6. Bypass poppet clogged

SPECIFICATIONS

PRO25-012
Designed to safely transfer low viscosity petroleum fuels such as gasoline (up to 15% alcohol blends
such as E15), diesel fuel (up to 20% biodiesel blends such as B20) and kerosene. Pump is designed
for permanent mounting on vented storage tanks.
Cast Iron
Up to 25 GPM (94 LPM)
30 min. ON, 30 min. OFF
Up to 15 feet (4.6 meters)
Up to 10 feet (3 meters)
Extreme Temperature Series pumps are capable of operation down to -40° F.
Any pump operation below -20° F has not been evaluated by UL.
12-volt DC
35 amps
2000 RPM, 4/10 hp (300 watts)
cULus Listed. Class I, Division 1, Group D
40 amp circuit breaker
15 feet of 10 gauge (4.6 meters)
40 amp
2 inch NPT
1 inch NPT
1 inch NPT
Buna-N Electrically Conductive Discharge Hose
1 in. NPT x 1 in. 18 ft. (5.5 m)
1 in. NPT Diesel
1 in. NPT Diesel
56.7 lbs/25.7 kg
N/A
CORRECTIVE ACTION
Pump only low viscosity fluids.
Clean filter assembly.
Duty cycle is 30 minutes ON and 30 minutes OFF.
Ball bearings damaged. UL Listing requires specific treatment for
motor replacement, contact factory.
Remove bypass poppet and clean.
-20° F to +125° F (-29° C to +52° C)
20 PSI
2000 RPM, 4/10 hp (300 watts)
cULus Listed. Class I, Division 1, Group D
15 feet of 10 gauge (4.6 meters)
Buna-N Electrically Conductive Discharge Hose
1 in. NPT x 1 in. 18 ft. (5.5 m)
PRO25-024
Up to 25 GPM (94 LPM)
30 min. ON, 30 min. OFF
Up to 15 feet (4.6 meters)
Up to 10 feet (3 meters)
24-volt DC
20 amps
20 amp circuit breaker
20 amp
2 inch NPT
1 inch NPT
1 inch NPT
1 inch Diesel
1 inch Diesel
N/A
56.7 lbs/25.7 kg