Status of RED LED Lights
4 lights lit
3 lights lit
2 lights lit
1 light lit
1 light extinguished after 5 times flash
Battery Charging
CAUTION:
Make sure that the AC voltage of the power source meets the requirement specified on the
nameplate of the charger.
Plug the battery charger (FFCL18-01) into the proper AC power source. The charging indicator
light will flicker in green color and the charger operates in standby mode.
FFCL18-01
Battery Charger Model
FFCL18-03
220-240V
Charging Voltage
3.0A
Charging Current
50-60Hz
Charging Frequency
Applicable Battery Pack Voltage
14.4-18V
(DC)
Applicable Battery Cartridge
4.0Ah
Capacity
Full Charging Time (Approx.)
90mins
Insulation Class
Double Insulation
Charging Operation
1. Plug the battery charger into the proper AC
power source. The charging indicator light
will flicker in green color and the charger
operates in standby mode.
Approx. Battery Power Left
≥3/4
≥1/2
≥1/4
<1/4
Low level
SCHARG-001
(FFCL18-04)
110V-240V
5.0Ah
100mins
2. Insert the battery pack fully into the battery charger and the charger starts charging.
The battery charger can detect some sort of failure caused by the battery and indicates by the
statuses of the red and green indicator lights.
When a failure occurs, remove the battery and then insert it into the charger again. If the failure
continues, change with a new battery. If the new battery can be charged, then the old battery
maybe damaged. If the charging indicator lights indicate same failure as before while changing
with a new battery, then the charger maybe damaged, take the charger to be repaired by qualified
-15-
serviceman. (Fig. 11)
The following chart lists the relations between the statuses of charging and charging indicator
lights.
Charge State
Icon
Charger Into The Power Sour
Charging
After Charging
Battery Abnormal
Battery Temperature Below
0℃or Over 45℃
Work Light
The white LED work light will be lit when pull the
switch trigger, allows for illumination of the work
area under unfavorable lighting conditions. (Fig.
12)
Continuous Use
If the tool is operated continuously until the battery cartridge has discharged, allow the tool to rest
for 15minutes before proceeding with a fresh battery.
Light Icon
Indicator State
Green
Red
Green Flick, Red off
Green off, Red on
Green on, Red off
Green Red Flick
Green off, Red Flick