Autonics Ai-M-42LA Manuel - Sayfa 15

Kontrolör Autonics Ai-M-42LA için çevrimiçi göz atın veya pdf Manuel indirin. Autonics Ai-M-42LA 16 sayfaları. Pulse train input type, servo system, dc type

Autonics Ai-M-42LA Manuel
两相步进电机马达样本闭环步进电机驱动器说明书 韩国Autonics步进伺服马达选型样本pdf资料
AiS Series
4) Motor temperature chart
Minimized heat generation by managing the current flowing
through the motor with load.
※Result of Autonics test
(Drives 50 times and stops 1 min. repeatedly
at 29±1℃ ambient temperature)
●L type of frame size 42mm motor
[℃]
50
45
40
35
30
Start
5
25
5) Tuning not required
Tuning is unnecessary even with load changes. (no gain tun-
ing)

Proper usage

Troubleshooting
1. When motor does not rotate
①Check the connection status between controller and driver, and
pulse input specifications (voltage, width).
②Check the pulse and direction signal is connected correctly.
2. When motor rotates to the opposite direction of the
designated direction
①When RUN mode is 1-pulse method, CCW input [H] is for
forward, [L] is for backward.
②When RUN mode is 2-pulse method, check CW and CCW
pulse input is changed.
3. When motor drive is unstable
①Check that driver and motor is connected correctly.
②Check the driver pulse input specifications (voltage, width).
Q-16
奥托尼克斯电子中国autonics电机热线 4006-022-002
A company
B company
Autonics
50
75
100[min]
Caution during use
Motor
1. Do not disassemble or modify the product.
It may cause malfunction due to small dregs. Once disassembling
the motor, its performance would significantly decline.
2. Do not impact the motor.
The air-gap, the distance between rotator and stator is processed
as 0.05mm, but if it is impacted, the balance of air-gap can be
broken and it may cause a malfunction.
This encoder consists of precision components. Therefore, if
it is dropped or has strong shock, it may lose the function or
generates wrong output pulses.
3. Using at low temperature
Using motors at low temperature may cause reducing maximum
starting / driving characteristics of the motor as ball bearing's
grease consistency decreases due to low temperature. (Note
that the lower the bearing's grease consistency, the higher the
bearing's friction torques.) Start the motor in a steady manner
since motor's torque is not to be influenced.
4. Temperature rise
The surface temperature of motor shall be under 100℃ and it
can be significantly increased by operation conditions. In this
case, use the cooling fan to lower the temperature forcedly.
5. Insulation resistance measurement, Dielectric strength test
When executing insulation resistance measurement or dielectric
strength test when motor and driver are connected, it may cause
damage to the unit.
6. Maintenance, Inspection
For using motor, it is recommended to Maintenance and
inspection regularly.
If motor has error, do not use the motor. Take maintenance and
inspection before using it.
Maintenance and inspection items are as below.
①Unwinding bolt and connection parts for the unit installation
and load connection
②Strange sound from ball bearing of the unit
③Damage and Stress of lead cable of the unit
④Connection error with driver
⑤Inconsistency between the axis of motor output and the center,
concentric (eccentric, declination) of the load, etc.
Driver
1. Caution for signal input
If the signal input supply is higher than rated supply in the
specification, connect the additional resistance to external part.
(Connect 3kΩ of resistance when applying 24V of power)
2. Caution for wiring
( ※ Autonics product is recommended)
① Use twisted pair (over 0.2mm
should be shorter than 2m.
② The thickness of cable should be same or thicker than the
motor cable's when extending the motor cable.
③ Must separate between the signal cable and the power cable
over 10cm.
3. Caution for installation
For heat radiation when installing this unit, contact this driver
base tightly with the metal surface. When using this unit,
overheat error occur, install a fan for heat radiation or change the
installation placement.
4. Caution for re-supplying power
Re-supply power after min. 1 sec. from disconnected power.
5. Motor vibration and noise can occur in specific frequency
period
①Motor vibration and noise can be lowered by change motor
installation or attach damper.
②Use the unit in a range without vibration and noise range by
RUN speed adjustment.
6. This product may be used in the following environments
①It shall be used indoor
②Altitude up to 2,000m
③Pollution degree 2
④Installation category Ⅱ
深圳 北京 上海 株洲 天津 青岛
2