Dynapower TurboBox NA211A-LD Hızlı Kurulum Kılavuzu - Sayfa 3

Ağ Donanımı Dynapower TurboBox NA211A-LD için çevrimiçi göz atın veya pdf Hızlı Kurulum Kılavuzu indirin. Dynapower TurboBox NA211A-LD 5 sayfaları.

NA211A-LD
External PCIe Slot Expansion Box
1. Loosen the thumbscrew and remove the top cover
of NA211A-LD.
Step 1
2. Remove one of the lids on rear of NA211A-LD for
installation of the SAS/SATA RAID/non-RAID card.
Step 2
WARNING: Using a screwdriver or tools to remove the lid to
avoid any injury to your finger.
3. Insert the SAS/SATA RAID/non-RAID card into one of
the PCIe ×8 slots, and then tighten the screw on the
riser to the NA211A-LD.
Step 3
WARNING: The slot blower has been fixed inside the
NA211A-LD to help with the ventilation.
Installation of 2.5" SAS/SATA hard
5.
disk drive or solid state drive on
NA211A-LD
1. Loosen the thumbscrew on drive tray. Pull out the
lever of tray, and then pull out the drive tray out of
the drive enclosure.
pull out
Step 1
2. Attach 2.5" SAS/SATA hard disk drive or solid
state drive onto the drive tray, and then tighten
four screws on drive tray. After four screws are
tightened on drive tray, insert the drive tray back
into drive enclosure.
Step 2
3. When four drive trays with 2.5" SAS/SATA hard
disk drives or solid state drives are within drive
enclosure inside NA210A-LD, connect the end of
mini-SAS data cable to mini-SAS connector on
SAS/SATA RAID/non-RAID card.
2
3
4
Step 3
4. Put the top cover back to the top of NA211A-LD, and then
tighten the thumbscrew on the top cover.
1
2
3
4
5. Connect the power cord to the power cord receptacle and
the end of PCIe ×4 data cable to the PCIe ×4 connector
on rear of NA211A-LD.
6.
Fan Speed Adjustment
You are able to adjust the speed of 80×80×25 mm cooling
fan on TurboBox NA211A-LD. To adjust the fan speed,
pull the 80×80×25 mm cooling fan out, and you will see
five sets of jumpers labeled with F, 1, 2, 3, and
4 respectively from left to right on the board.
The default setting is the jumper being placed over pin 9
and pin 10 for label 4, meaning the slowest speed of fan.
If the jumper is placed over pin 1 and pin 2 for label F,
the fan will spin at full speed. From label 1 to label 3, the
fan speed decreases. If all of the pins are open (meaning
no jumper is placed over the pins), the fan will not spin.
7.
Installation of host adapter card and
SAS/SATA RAID/
non-RAID card

cable connection

2
4
6
8
10
1
3
5
7
9