Mainsboost Charger MBC 450SV Kurulum, Çalıştırma ve Bakım Talimatları Kılavuzu - Sayfa 12
Su Pompası Mainsboost Charger MBC 450SV için çevrimiçi göz atın veya pdf Kurulum, Çalıştırma ve Bakım Talimatları Kılavuzu indirin. Mainsboost Charger MBC 450SV 20 sayfaları. Multi water performance system
6.18 Wiring diagram:
E
GREEN/YELLOW
230 VAC/1PH/50Hz
N
BLUE
SUPPLY
BROWN
L
MAIN WINDING
THERMOTRIP
CAPACITOR
START WINDING
Fig. 7
6.19 Fuse: All models should be protected by a 3 Amp fuse.
6.20 Supply cord replacement:
6.21 If the supply cord is to be changed or damaged, it must be replaced by a special
cord available from Stuart Turner or one of its approved repairers.
BROWN
12 VAC
N N1 N2 L5 L4 L3 L2 L1 L
BROWN
The internal wiring within the terminal box is routed and
secured to ensure compliance with the electrical standard
EN 60335-1. It is essential that prior to any disturbance of
this internal wiring, all cable routing and securing details are
carefully noted to ensure re-assembly to the same factory
pattern is always maintained.
BLUE
BROWN
BLUE
BLACK
TEMPERATURE
SENSOR
- 12 -
BLUE
BLACK
BROWN
BROWN
BLUE
BLUE
NOT USED
BROWN
BLUE
BROWN
BLUE
BROWN
PRESSURE
SENSOR
1
2
3
4
5
6
CONTROLLER
7
8
9
NOT USED
10
11
12 -VE
13 +VE
Cont ...