Gammaflux GLC 2k Kurulum Kılavuzu

Kontrolör Gammaflux GLC 2k için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Gammaflux GLC 2k 4 sayfaları.

GLC 2k
Advanced Setup/Troubleshooting
• Hot Runner Temperature Controller
• 12 Zone Maximum per Tier
• 1 HBE-24 Female Connector for
Power per Tier (Standard)
• 1 HBE-24 Male Connector for
Thermocouple per Tier (Standard)
• Remote Mount Alarm Relay
• External Communications RS232/RS485
Version 1.3
GLC 2K Start Up Procedure
1
Dry Cycle Mold, Apply Full Tonnage, 3-4 Times (Pinch any wires in
advance of operation)
2
Turn Individual Zones "Off "
3
Turn "On" Main Disconnect
4
Select Zone or Zones, Press 1st Zone, Hold, Press Last Zone, Hold, Release.
All Zones Lit are Selected
5
Change Area – Select Temperature Set, Enter Set Point, Press Enter, All
Zones Selected will Change
6
Select Zone or Zones, Press 1st Zone, Hold, Press Last Zone, Hold, Release.
All Zones Lit are Selected
7
Change Area – Select Automatic/Manual Selection, Enter "0" for Automatic
Operation, Press Enter
8
Turn "On" Zone Power Switch. Apply Power to Manifolds first if required
by Manifold Supplier
9
Zones will read a Low Temperature Alarm, Zones are close or holding Set
Point When the Green Temperature Holding Set Point Light is Illuminated
Temperature Set
Enter
Gammaflux
Sterling, VA USA Tel. +1-(703) 471-5050
Wiesbaden, Germany Tel. +49-(0)-611-973430
Ube, Japan Tel. +81-(836) 54-4369
www.gammaflux.com; www.gammaflux.de
Select
Automatic/
Manual Selectionl
Select
Zone select indication
Temperature holding set point
Low temperature alarm