Non-Vented
(recirculating)
Installation
1. Connect the deflector to the vent cover bracket using the four
3.5 x 9.5 mm screws 3rovided.
i
4=
Run 3 wires, black, white and green (14AWG), in 1/2"conduit
from service panel to terminal box. Use caulking to seal
opening.
A
B
B
A. Vent cover bracket
B. 3.5 x 9.5 mm screws
2. Measure length of 8" (20 cm) vent needed to connect the
transition to the deflector.
NOTE: Vent should fit up inside deflector a minimum of
1" (2.5 cm).
3. Install vent between the transition and the deflector.
4. Seal all connections
with clamps.
5. Remove grease filter.
Mc,, <®Eecff
Connect on
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect
power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved 1/2"strain relief.
/
C
D
F
A. UL listed or CSA approved strain relief
B. Home power supply cable
C. Terminal box
D. Black wires
E. Green (or bare) wire connected
to yellow-green
wire
F. White wires
5. Use UL listed wire connectors
and connect black wires (D)
together.
6. Use UL listed wire connectors
and connect white wires (F)
together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground
wire to green and yellow ground wire
in terminal
box.
Failure to do so can result
in death or electrical
shock.
7. Connect green (or bare) ground wire from home power supply
to yellow-green
ground wire (E) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check all light bulbs to make sure they are secure in their
sockets.
11. Reconnect power.
10