Alive Air Air Purifier Kullanıcı El Kitabı - Sayfa 12

Hava Temizleyici Alive Air Air Purifier için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Alive Air Air Purifier 17 sayfaları. Alive air 9-stage air purifier owner’s manual
Ayrıca Alive Air Air Purifier için: Kullanıcı El Kitabı (17 sayfalar)

CLEANING AND MAINTENANCE ( Cont. )
Note: The 'Replace Filter' indicator operates on a preset timer. So, if
the indicator is flashing and an inspection of the HEPA filter, compared
to a white sheet of paper, confirms it's NOT brownish or greyish, you
can simply reset the timer as instructed below. If the HEPA filter DOES
appear brownish or greyish, remove and replace the filter as instructed
on page 7 and then reset the 'Replace Filter' indicator.
Remove the Face Plate, Pre-Filter, Electronic Grid, HEPA/Charcoal filter and TiO2 filter as shown on page 7.
The bulb has two wing-like protrusions at the end of the black area on each side that fit into left and right UV slots on the
unit.
Without touching the actual glass bulb
push it towards the right spring loaded UV slot. To successfully unlock the bulb, you may have to turn it 1/4 of the way
towards you. While still pushing the bulb to the right, pull the bulb towards you and it should release from both slots.
Reverse the above process when installing the new bulb. Hold the wing-like protrusions on each side of the new bulb in
the 12:00 and 6:00 positions to align with the unit's UV slots. Insert the bulb into the right hand spring loaded side first.
then the left hand side and turn the bulb 1/4 turn towards the machine locking the bulb in position.
For additional visual instructions, see the Video Instruction called: "Changing the UV Bulb" at
http://aliveairpurifier.com/alive-air-video-help/
IMPORTANT: Both these indicators are pre-set at the factory to light up after approximately 6 months. Neither indicator is
directly tied to whether filters are in need of cleaning or if the HEPA/Charcoal Filter needs replacing. If you've already cleaned
the metal grid once a month and properly maintained and replaced the HEPA/Charcoal filter as outlined in this manual, then
when either of these lights come on, simply reset them as indicated below.
HI
ION-UV INDICATOR
MED
LOW
QUIET
AUTO
CLEAN AIR MONITOR
FLOW
ODOR DUST ALLERGEN
POWER
Alive Air 9-Stage Air Purifier Owner's Manual
The UV bulb lasts about 5,000 hours. Replace it when a.) it is damaged; b.) when no
blue light is observed at night, when standing behind the unit, looking down through the
vents on top the unit;
OR
, grab the black section of the bulb that's inserted on the left UV slot and
8HR
CLEAN METAL GRID
2HR
REPLACE FILTER
1HR
RESET
TIMER
11
c)
at least every 12 months
HI
MED
LOW
QUIET
AUTO
FLOW
.
ION-UV INDICATOR
8HR
CLEAN METAL GRID
2HR
REPLACE FILTER
1HR
RESET
CLEAN AIR MONITOR
TIMER
ODOR DUST ALLERGEN
POWER