12.3 Replacing the power cord plug

Only authorized personnel may replace the
power cord plug.
All alkitronic
®
NOVA Hydraulic Power Units have a
three-wire power cord. Only authorized personnel
may replace the power cord plug.
After connecting, perform an electric safety inspec-
tion. Metal housing must be grounded! Improper
connection may cause electric shock, resulting in
personal injury or death.
NOVA
electrical hydraulic pump
Power cord plug
15
Procedure:
1. Disconnect alkitronic® NOVA Hydraulic Power Unit from
the power supply (pull power cord plug).
2. Separate the plug from the power cord.
N
Neutral conductor
(blue)
PE
Ground conductor
(yellow and green)
L
Outer conductor
(black or brown)
Materials and specifications are subject to change without notice.