Fujitsu UTY-RNRUZ2 Kullanım Kılavuzu - Sayfa 15

Klima Fujitsu UTY-RNRUZ2 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Fujitsu UTY-RNRUZ2 26 sayfaları. Remote controller (wired type)
Ayrıca Fujitsu UTY-RNRUZ2 için: Kurulum Kılavuzu (11 sayfalar)

Fujitsu UTY-RNRUZ2 Kullanım Kılavuzu
When the [OK] is touched, the display returns to "Set
Temp. Auto Return" screen.
Set the Return Time and Temperature
(4) Touch the [Return Time/Return Temp.] on the "Set
Temp. Auto Return" screen.
(5) "Setting" screen is displayed. When the [Cool/Dry] or
[Heat] on the "Setting" screen is touched, the time and
temperature setting screen is displayed.
(4)
Set Temp. Auto Return
Enable /Disable
[Enable]
Return Time / Return Temp.
Cool/Dry
60min. / 84°
F
Heat
60min. / 74°
F
Cancel
OK
(6) Set the time and temperature
by touching [ ] or [ ]. The
time can be set within the 10
to 240 min. range in 10 min.
increments.
When the [OK] is touched, the
display returns to the "Setting"
screen.
Note
When [Schedule Temp.] is touched, the weekly timer icon
is displayed at the temperature display. When "---ºF (or
---ºC)" is displayed at the temperature display, schedule
is not set. Refer to [3-4 Weekly Timer Setting].
(7) When the [Back] is touched, the display returns to the
"Set Temp. Auto Return" screen.
Apply the setting.
(8) Touch the [OK] on the "Set
Temp. Auto Return" screen.
After the setting change
screen is displayed, the
display returns to the "Special
Setting" screen.

3-5-3 Set Temp. Range Setting (for administrator)

(1) Touch the [Set Temp. Range
Setting] on the "Special Set-
ting" screen. When the "Pass-
word Verification" screen is
displayed, enter the password
and touch the [OK].
"Set Temp. Range Setting" screen is displayed.
Enable the Set Temp. Range Setting
(2) Touch the [Enable/Disable] on the "Set Temp. Range
Setting" screen.
(3) "Enable/Disable" screen is displayed. Touch the [Enable]
on the "Enable/Disable" screen.
(2)
Set Temp. Range Setting
Enable /Disable
[Disable]
Lower Limit
Upper Limit
Cool/Dry
64
°F
88
°F
Heat
48
°F
88
°F
Cancel
OK
When the [OK] is touched, the display returns to the "Set
Temp. Range Setting" screen.
(5)
Setting
Cool/Dry
60min. / 84°
F
Heat
60min. / 74°
F
Back
Cool/Dry
Return
Return
Time
Temp.
60
84
Schedule
min
°F
Temp.
Cancel
OK
Set Temp. Auto Return
Enable /Disable
[Enable]
Return Time / Return Temp.
Cool/Dry
60min. / 84°
F
Heat
60min. / 74°
F
Cancel
OK
Special Setting
Page 1/ 2
Set Temp.
Economy
Auto Return
Set Temp.
Anti Freeze
Range Setting
Next
Back
Page
(3)
Enable/Disable
Enable
Disable
Cancel
OK
Set the Lower Limit and Upper Limit
(4) Touch the [Lower Limit - Upper Limit] on the "Set Temp.
Range Setting" screen.
(5) "Setting" screen is displayed. Touch the [Cool/Dry] or
[Heat] on the "Setting" screen.
(4)
Set Temp. Range Setting
Enable /Disable
[Enable]
Lower Limit
Upper Limit
Cool/Dry
64
88
°F
°F
Heat
48
88
°F
°F
Cancel
OK
(6) Each setting screen is dis-
played. Set the temperature
upper limit and lower limit by
touching [ ] or [ ].
When the [OK] is touched, the display returns to the
"Setting" screen. If the [Back] on the "Setting" screen is
touched, the display returns to the "Temp. Range Set-
ting" screen.
Note
The settable upper limit value and lower limit value may
be different depending on the indoor unit model and set-
ting at installation.
Apply the setting.
(7) Touch the [OK] on the "Set
Temp. Range Setting" screen.
After the setting change
screen is displayed, the
display returns to the "Special
Setting" screen.

3-5-4 Anti Freeze (for administrator)

(1) Touch the [Anti Freeze] on
the "Special Setting" screen.
When the "Password Verifica-
tion" screen is displayed, enter
the password and touch the
[OK].
On/Off of the Anti Freeze
(2) "Anti Freeze" screen is dis-
played. Select the [On] or [Off]
on the "Anti Freeze" screen.
When the [OK] is touched, data transmission is per-
formed and after the setting change screen is displayed,
the display returns to the "Special Setting" screen.
Note
When this function is used together with Away Setting,
setting by Away Setting is necessary. Refer to [3-5-5
Away Setting].
(5)
Setting
Cool/Dry
[64°
F
– 88°
F
]
Heat
[48°
F
– 88°
F
]
Back
Cool/Dry
Lower Limit
Upper Limit
64
88
°F
°F
Cancel
OK
Set Temp. Range Setting
Enable /Disable
[Enable]
Lower Limit
Upper Limit
Cool/Dry
64
88
°F
°F
Heat
48
88
°F
°F
Cancel
OK
Special Setting
Page 1/ 2
Set Temp.
Economy
Auto Return
Set Temp.
Anti Freeze
Range Setting
Next
Back
Page
Anti Freeze
On
Off
Cancel
OK
En-14