What to do if ...
Correcting Malfunctions
A malfunction may be caused by only a minor fault that you can rec-
tify yourself using the following instructions. Do not perform any
other work on the appliance if the following information does not
provide assistance in your specific case.
Important! Repairs to refrigerators/freezers may only be performed by
competent service engineers. Improper repairs can give rise to signifi-
cant hazards for the user. If your appliance needs repairing, please
contact your specialist dealer or your local Service Force Centre.
If the freezer system has stopped working and the freezer is full, the
reserve
time of about 22 hours.
Appliance does not work,
no pilot light is
illuminated.
Appliance cools too much.
The freezer temperature is
not sufficient, red light
illuminates, temperature
alarm signal sounds.
22
in the deep frozen food itself will give the food a hold over
Symptoms
Possible Cause
Appliance is not switched
on.
Mains plug is not plugged
in or is loose.
Fuse has blown or is
defective
Socket is defective.
Temperature is set too
cold.
Temperature is not proper-
ly adjusted.
Door was open for an
extended period.
A large quantity of warm
food placed in the appli-
ance within the last 24
hours.
The appliance is near a
heat source.
Remedy
Switch on the appliance.
Insert mains plug.
Check fuse, replace if
necessary.
Mains malfunctions are to
be corrected by an
electrician.
Turn the temperature reg-
ulator to a warmer
setting temporarily.
Please look in the "Initial
Start Up" section.
Do not leave the door
open any longer than nec-
essary. Press the fast freeze
switch.
Press the FROSTMATIC
button.
Please look in the
"Installation Location"
section.