If any problem occurs, please detach the plug from the
socket and contact Euro-Parts or a similarly qualified
person in order to avoid a hazard.
Problem
Light on, but
motor does not
work
Light does not
work, motor
does not work
Vibration
Insufficient
suction effect
Trouble Shooting
Cause
The outlet valve is
blocked
The capacitor has
failed
The control switch
has broken
No power supply
Fuse has blown
The propeller is
damaged or
unbalanced
The hood is not
installed correctly
The distance
between the hood
and cooktop is too
great
The filters are
saturated
Solution
Detach flue and duct
then turn on the hood
to check if the valves
open
Call for technical
service
Call for technical
service
Plug another appliance
into the socket to
confirm there is power
supply
Open up the plug and
replace he 13A fuse
Call for technical
service
Review the installation
instructions and check
the installation again
for loose screws,
brackets or
connections
Check that the
distance is between
600mm and 762mm
Clean the filters from
grease residue and
replace after cleaning
9
|