AEG LAVATHERM 56600 Kullanım Talimatları Kılavuzu - Sayfa 26

Kurutucu AEG LAVATHERM 56600 için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. AEG LAVATHERM 56600 40 sayfaları. Condenser dryer

AEG LAVATHERM 56600 Kullanım Talimatları Kılavuzu
Something not working?
The drum illumination does
not work
The drying process takes
unusually long
The door cannot be closed
Display EMPTY WATER is lit
EMPTY WATER indicator illu-
minated, even though the
container has already been
emptied
If after these checks, the tumble dryer still does not work, contact your
local AEG Service Force Centre.
Please note that it will be necessary to provide proof of purchase for
any in-guarantee service calls.
In-guarantee customers should ensure that the above checks have been
made as the engineer will make a charge if the fault is not a mechani-
cal or electrical breakdown.
26
Symptom
Possible cause
Is the tumble dryer
plugged in
The program selector is in
the OFF position
The bulb needs replacing
The condenser unit is
covered with fluff
Fluff filter is clogged
Fluff filter has not been
inserted correctly and/or
the filter lid not closed
Condensate container full
Foreign bodies, e. g. ani-
mal hairs, can block the
inlet nozzle as well as the
valve on the end of the
EMPTY WATER container
Solution
Plug in the tumble dryer
Turn the program selector
dial to LIGHT
Replace bulb
Clean the condenser unit
Clean the fluff filter
Replace the fluff filter
and ensure the filter lid is
closed
Empty the condensate
container
With the container pulled
out, switch on the
appliance momentarily.
The blockage can be
removed from the contai-
ner shaft or the hair clea-
ned out of the valve