F I R S T
T O
D I V E
COPYRIGHT
This manual is the property of Aqualung France. Any
copying, photocopying, reproduction, translation, electronic
distribution (email, Internet...), even partial, and in whatever
format, is expressly forbidden without the written consent of
Aqualung France.
©2005 Aqua Lung France.
INTRODUCTION
This manual gives the instructions and the recommendations
for the disassembly, the cleaning, the checking, the
reassembly and the adjustment of an Aqualung regulator.
This manual is not an instruction manual for unqualified
personnel. The procedures described in this manual are
intended only for qualified personnel who have been trained
in the servicing of Aqualung equipment during a specialised
course.
If you do not understand certain procedures in this manual
you should contact an Aqualung service consultant before
undertaking any operation.
WARNINGS, ATTENTION, NOTES
Certain icons have been used to facilitate the reading and
understanding of this manual. They have the following
meanings:
WARNING: Indicates situations that could result in
serious or fatal accidents if the advice given is not
followed correctly.
.
ATTENTION: Indicates a situation or action that
could cause serious damage to the product,
making it dangerous if the advice given is not
followed correctly.
NOTE: Notes are used to emphasize
important points as well as information that
needs to be remembered.
MAINTENANCE
Attention:
carried out during a year, the regulator should
receive a complete service each year. If the
regulator
is
aggressive environment the service period
should be reduced to six months.
In order to conform with the Aqualung Regulator
Lifetime Guarantee, all servicing (inspection, servicing
and repairs) should be recorded in the Service Record
incorporated in the regulator User Manual.
Whatever the number of dives
used
in
a
chlorinated
GENERAL INSTRUCTIONS
1.
In order to carry out the procedures described in this
manual correctly it is important that you follow the steps
in the exact order indicated. Read the manual through
completely so that you become familiar with all the
procedures, the special tools and the replacement parts,
before starting to disassemble the product. Keep this
manual open near to you so that you can refer to it step
by step. Do not rely on your memory.
2.
All servicing and repair procedures should be carried
out in a workshop that is clean, well lit, easy to access
and specially fitted for the purpose.
3.
The regulator body should never be directly held in the
jaws of a vice. To hold the body, screw the tool 116230
into the HP port and then grip the tool with the vice.
4.
Once the regulator has been disassembled, the re-
usable components should be separated from the
components that need to be replaced. Fragile items with
seats or crowns with critical sealing surfaces should be
separated and protected during servicing in order to
prevent any damage.
5.
Use only spare parts from Aqualung service kits. Never
replace an Aqualung part with one from another
manufacturer, even if it appears similar.
6.
Never re-use regulator parts which should be replaced
on the pretext that the regulator has seen little use since
its manufacture or since its last service.
7.
When reassembling, check that the torque used
conforms with that shown in Table 4, Torque. Some
parts can be irretrievably damaged if the acceptable
torque is exceeded.
GENERAL CONVENTIONS
The conventions described below define the actions to be
carried out when an instruction is given.
1.
Unscrew: to unscrew a threaded part, turn it anti-
clockwise.
2.
Screw: to screw a threaded part, turn it clockwise.
3.
Remove the O-ring: To remove an O-ring follow the
method below, using the special tool provided for this
purpose. Any tool that could damage the O-ring should
be avoided. In every case, replace the O-ring removed
with a new one.
Press simultaneously on the
two sides of the O-ring in
or
order to form an 'eye'. .
Insert the special tool into this
eye to remove the O-ring.
4.
The acronyms used:
LP: Low Pressure
MP: Medium Pressure
HP: High Pressure
3