Connect Three or More S60 Systems

2-port, 12G Stacking Modules
As an option, when using the 2-port, 12G stacking modules, insert a second cable into the other open
stack ports
(Figure
3-5). The second cable provides both backup connectivity and increased data transfer
between the systems.
To connect 2-port, 12G stacking modules, starting with the S60 system at the bottom of the stack:
Step
Task
Insert one end of the first cable into Stack Port 48 (or 50).
1
Insert the other end of the cable into Stack Port 48 (or 50) of the middle S60 system.
2
Insert the second cable into Stack Port 49 (or 51) of the middle and top S60 systems.
3
Use the remaining cable to connect the top and bottom S60 systems by inserting one end of the cable into the open
4
Stack Port 49 (or 51) of the bottom S60 system and the other end of the cable into Stack Port 48 (or 50) of the top
S60 system.
Figure 3-5. Three S60 Systems with 2-port, 12G Stacking Modules Connected in a Ring Topology
1-port, 24G Stacking Modules
The 1-port, 24G stacking module requires the S60 systems be cabled from the front-ports-to-rear-port, or
vice versa
(Figure
3-6).
To connect 1-port, 24G stacking modules, starting with the S60 system at the bottom of the stack:
Step
Task
Insert one end of the first cable into Stack Port 48 (or 50).
1
Insert the other end of the cable into Stack Port 48 (or 50) of the middle S60 system.
2
Insert the second cable into Stack Port 50 (or 48) of the middle and top S60 systems.
3
Use the remaining cable to connect the top and bottom S60 systems by inserting one end of the cable into the open
4
Stack Port 48 (or 50) of the bottom S60 system and the other end of the cable into Stack Port 50 (or 48) of the top
S60 system.
Install the S60 System
|