If site conditions are not suitable for the
cooker hood to be used for air
extraction the appliance must be
connected for recirculation.
The following parts, available through
your Miele Dealer or from the Miele
Spare Parts Department are required
for operating the appliance in
recirculation mode:
– Conversion kit for
recirculation mode
(C 125 mm):
exhaust grille,
hose, hose clip
– 2 Active charcoal
filters (see
"Technical data")
^ When fitting the cooker hood in a wall
unit the exhaust grille b has to be
fitted in the top of the unit.
^ The exhaust connection a and the
exhaust grille b are joined together
using a suitable hose or flexible
ducting c.
If the front of the unit is ceiling height
(i.e, extractor canopies, ceiling
mounted units) then an appropriate
cut-out must be made in the front
panel d .
When fitting the ventilation grille make
sure that the slats in the grille point
towards the centre of the room and
not directly towards a wall or the
ceiling.
^ Install the active charcoal filters (see
"Cleaning and care").
^ Connect the appliance to the mains
via a fused spur or fused socket as
appropriate.
Before connecting the appliance
read the safety notes in "Warning
and Safety instructions" and in the
"Electrical connection" section.