Connection for air extraction
Connection for air extraction
Danger of toxic fumes
Please follow the advice in the sec-
tion "Warning and safety instruct-
ions" very carefully.
The cooker hood should be in-
stalled acording to local regulations.
Seek approval from the buildings in-
spector where necessary.
Connection
– The extraction ducting should be as
short and straight as possible.
– Use large radius bends. Narrow
bends reduce the efficiency of the
cooker hood.
– Pipes made from non-flammable ma-
terials only may be used for extrac-
tion connection.
Type of bend
Smooth walled bend
Elbow
Bend in concertina
hose
Flexible piping
Data quoted in brackets for pipe with Ø 100 mm.
16
Angle of bend
90°
90°
45°
45°
90°
45°
90°
90°
90°
90°
45°
45°
45°
– If the extraction ducting is to be laid
horizontally, it should slope down-
wards away from the cooker hood
with a minimum incline of 1 cm per 1
metre of ducting to prevent con-
densed water from running back into
the appliance.
Calculating the extraction ducting
A pipe of diameter 120 mm (100 mm)
should guarantee trouble-free extrac-
tion by the cooker hood up to a total
pipe length of 34m (16m).
Determine the total pipe length as fol-
lows:
Measure the total length of the ex-
traction ducting to be used.
Add the appropriate equivalent
length of additional piping to this fig-
ure, according to the number and
type of bends (see table).
Radius of bend in mm
125 (100)
250 (200)
125 (100)
250 (200)
125 (100)
250 (200)
500 (400)
125 (100)
250 (200)
500 (400)
Additional piping
length in m
0.3 (0.4)
0.2 (0.3)
0.2 (0.3)
0.1 (0.1)
2.0 (2.3)
0.5 (0.6)
0.7 (0.75)
0.35 (0.4)
0.3 (0.35)
0.2 (0.3)
0.2 (0.25)
0.15 (0.2)
0.1 (0.2)