ABB C1960 Ürün Uygulama Kılavuzu - Sayfa 2

Endüstriyel Ekipmanlar ABB C1960 için çevrimiçi göz atın veya pdf Ürün Uygulama Kılavuzu indirin. ABB C1960 8 sayfaları. Retort control in the food industry, industrial it enabled

ABB C1960 Ürün Uygulama Kılavuzu
Retort Control in the Food Industry using the C1960
Why Use a C1960?

Features and Benefits

The
ensures high quality retorting and productivity. Features making it ideal for
C1960
retorts include:
Automatic temperature control for increased production and operational efficiency.
Up to ten set point profiles, including guaranteed ramp and soak with individual
hysteresis for precise temperature profiles and improved product quality.
Dedicated front panel for Ramp/Soak profile applications.
Three displays showing target set point, time remaining in segment and current
segment running.
Fast startup with self-seeking set point.
Direct-connected RTD and/or thermocouple inputs reduce installation costs.
Easy-clean NEMA4X/IP66 front face.
Precise Set-Point Profiles Improve Quality, Consistency and Yield
The C1960 features a Ramp/Soak set point profile generator with configurable
hysteresis. It can be programmed with up to 10 temperature profiles and has a
maximum of 99 segments that can be distributed throughout the programs.
Configurable hysteresis provides the flexibility to set the upper and lower limits of
both ramp and soak segments to achieve a particular process requirement.
A guaranteed process ramp is provided as part of the C1960 profile. This feature
is useful in situations where steam fluctuations may occur. For example, when
ramping the process to the desired temperature set point, the guaranteed process
ramp tries to ensure that the process keeps pace with the rising set point. If it
cannot, the set point ramp is delayed until the process is within the specified
hysteresis band.
The guaranteed soak ensures that the temperature and duration of the soak are
held to the configured set points.
Comprehensive Displays for Improved Operation
The large, dedicated ramp/soak front panel display of the C1960 allows the
operator to see displayed information from a distance. This information includes
the target set point, time remaining in main soak segment and the segment running.
The controller also includes status indicators to show if the profile is in a ramp or
soak segment. Dedicated keys allow simple control of the profile. The keys are:
Run
Hold
Stop
Increase Time/Temperature
Decrease Time/Temperature
Direct Connecting I/O Reduces Installation Costs
With the C1960, RTD or thermocouple inputs are connected directly to the
instrument. Linearization and ranging are automatic. This not only simplifies
installation but also reduces installation costs by eliminating the need for special
termination panels or conversion equipment.