aquatherm AT600 İşletme Sahibi Kullanım Kılavuzu - Sayfa 8

Isı Pompası aquatherm AT600 için çevrimiçi göz atın veya pdf İşletme Sahibi Kullanım Kılavuzu indirin. aquatherm AT600 12 sayfaları. Swimming pool & spa heat pumps
Ayrıca aquatherm AT600 için: İşletme Sahibi Kullanım Kılavuzu (12 sayfalar), Kurulum Kılavuzu (16 sayfalar)

Heat Pump Maintenance & Precautions
1. Air Flow & Service Access
Clearances
BASE
(CONCRETE OR
PREFAB)
1. Make sure the unit has a firm base. The heat pump will produce condensation
(water) while in operation. You will notice water coming from the bottom drain
ports when the unit is running. The condensation will increase as the outdoor
air humidity level increases.
Make sure the bottom drain ports do not become clogged with debris. Make
sure the run off water does not puddle inside the heater and does not undermine
the equipment base.
2. Keep the top air flow discharge & air flow intake area clear as shown here so
the air flow through the heater is not restricted. Make sure the unit can "breathe"
well. The cooler discharge air from the top should not accumulate and be drawn
into the side air intake coils. Keep all plants and shrubs trimmed away from the
heater. Make sure the front is accessible for future service.
3. Do not allow lawn sprinklers to spray on the heater in any way. Keep sprin-
kler heads away from the heat pump to prevent corrosion and damage. Use a
deflector if needed.
4. If the unit is installed under a steep roof pitch or under a roof valley that has
no gutter, a gutter or diverter should be fitted to prevent excessive water from
pouring through the unit.
AIR COIL
(on 3 Sides)
60"
FRONT
2"
Page 8
BACK
AIR
12"
COIL
12"
FRONT
36"
6'
12"