Special features
The IntenZ CB-150 is equipped with special features, which enhance the performance of the fixture and also
provide more user convenience.
I.T.M. (Intelligent Temperature Monitoring):
Temperature controlled fan cooling
The internal fan of the unit is temperature controlled, which means that the fan will only turn on if needed. For
theatrical and other applications where fixtures need to be as silent as possible, this provides lots of
convenience. When the fixture is not used (in blackout mode, or used with low output), the fan will not turn
on.
The internal fan will turn on when the temperature sensor detects a temperature between 40 and 60 degrees
Celsius. At first, the fan will turn on in low power mode, thus being very silent but still cooling. When the unit
detects that the temperature has not changed (or even increased), the speed of the fan will increase to its
maximum level (when the temperature reaches 60 degrees Celsius).
Temperature controlled power limit protection
When working in extreme environments (especially high temperature environments such as clubs or sunny
outdoor festivals) it is important for the drivers and LED modules to stay intact and be reliable. Therefore, the
IntenZ CB-150 is equipped with a power drop protection, which decreases the LED output when the
temperature of the fixture exceeds 60 degrees Celsius. For every degree above the 60 degrees limit, the
output power will be decreased with 5%.
Temperature controlled protect mode
When the temperature of the fixture exceeds 68 degrees Celsius, the critical maximum temperature limit is
reached and the LED output of the fixture will be shut down automatically. A cool-down time is applied until
the temperature decreases back to 60 degrees Celsius.
When the temperature of the fixture does not decrease after several shut-down actions, check the following:
- Is the fan still working?
- Is the fan blocked?
- Is the environment temperature too high?
- Is the fan sucking hot air into its ventilation system?
- Is the fixture too close to other (hot) objects?
If you are unable to solve temperature problems, shut down the fixture completely and check if the fixture still
works when you connect it in a colder area. If you have any problems with the functionality of the fixture after
this check, contact your local dealer or a skilled technician to inspect the unit.
S.L.S. (Signal Loss Setting):
The Signal Loss Setting system can be used to program a secondary working mode when the DMX mode
fails, for example due to a loose cable. The secondary mode is set to Black out mode in default (which shuts
down the output of the fixture until a proper DMX-signal is detected). By switching off the Black out mode, the
fixture will turn to sound controlled operation when DMX-signal is lost.
In most situations, the Black out mode is used for professional environments (which prevents mismatching
colours and chases) and Sound controlled operation is selected for more small-scaled applications, which
prevents total black out.
I.M.S. (IntenZ Matrix System):
The IntenZ CB-150 is equipped with the special IntenZ Matrix System, which makes it possible to mount
several fixtures in a matrix setup. Vertical coupling of the fixtures is possible (to make large setups with 5 CB-
150 fixtures / 25 pixels in a row). Horizontal coupling when the fixture is in vertical position is also possible,
which creates a 5x5 matrix panel, made from 5 CB-150 fixtures.
NOTE: Always attach the included safety pins! If lost, contact your local dealer for replacements.