2 Abrasive Regulator
Description:
The Abrasive Regulator is positioned over the cutting head and is fed abrasive from the abrasive
delivery pot. The Regulator will provide an accurate metering and control of the abrasive flow rate. The
regulator uses an air cylinder to turn the abrasive flow to the cutting head ON or OFF. An adjustment
control knob is used to meter the abrasive rate to the cutting head.
2.1 Regulator Installation
Location
The Metering Regulator is mounted to the Z-axis faceplate over the cutting head at up to 6' (feet) from
the floor level. This should be high enough to keep the regulator out of the spray-back area from the
cutting head and within reach for adjusting the abrasive flow rate.
Attaching the Regulator to the
Machine
1. Remove the back mounting plate from the
regulator. Use the mounting plate to position and
drill mounting holes on the machine.
NOTE: The holes on the mounting plate are
positioned 2 inches (50.8 mm) on center from each
other and counter bored for .25 (6.35 mm)
Capscrews.
2. Reassemble the back mounting plate to the
regulator.
3. Remove the bottom adapter from the regulator and
thread the rear tie rod upward so that there is
access to mount the regulator to the machine. Use
¼" (6 mm bolt) cap screws for mounting the
regulator.
4. Re-thread the tie rods back into their original
locations.
13096 Abrasive Regulator II Manual
Picture may differ from
your regulator
2
Inlet
3/8 inch (9.524 mm)
Back Mounting
Plate see Note
Rear
Tie Rod