Siemens EC9A5SB90A Kullanıcı Talimatları - Sayfa 8

Hob Siemens EC9A5SB90A için çevrimiçi göz atın veya pdf Kullanıcı Talimatları indirin. Siemens EC9A5SB90A 20 sayfaları. 90 cm gas cooktop
Ayrıca Siemens EC9A5SB90A için: Kullanıcı Talimatları (20 sayfalar)

Siemens EC9A5SB90A Kullanıcı Talimatları
Installation and connection
en
Ignite all burners both individually and concurrently to
ensure correct operation of gas valves, burners and
ignition. Turn gas taps to low flame position and
observe stability of the flame for each burner
individually and all together. Adhere the duplicate data
plate to an accessible location near the hotplate. When
satisfied with the hotplate, please instruct the user on
the correct method of operation. In case the appliance
fails to operate correctly after all checks have been
carried out, refer to the authorised service provider in
your area.
It should be expressly noted that we cannot accept any
liability for direct or indirect damage caused by wrong
connection, leakage or improper installation. When
being repaired, the appliance must always be
disconnected from the mains supply; if required, notify
our customer service.

Converting the cooktop from Nat. Gas to

Universal LPG

All work involved in installation, setting and adaptation
to a different gas type must be carried out by
authorised personnel from our Service Centre and must
comply with current regulations and the conditions laid
down by the local gas company.
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
Important: After finishing, stick the sticker, indicating
the new gas type, close to the specifications plate.
Replacing the injectors
Request change-over injectors from our customer
service deparment (refer injector chart below for sizes).
Natural Gas
Hourly Gas
Consumption
(MJ)
Economy
4
burner
Standard-
output
6.85
burner
High-output
11
burner
Dual wok
burner
19.5
5 kW
Remove all pan supports, burner caps and
1.
distributors.
To replace the injectors, use the key that is available
2.
from our technical service with code 340847 (for
double-flame burners 340808). See table. It is
important to make sure that the injector does not
become detached during removal or fastening. They
must be properly tightened to ensure that there are
no leaks.
With these burners, there is no need to adjust the
primary air.
8
Universal LPG
Hourly Gas
Injector
Injector
Consumption
mark
(MJ)
88
3.5
116
6
153
11
190
16.5
77
Fasten the distributors and burner caps to the
3.
corresponding burners. In addition to this, put the
pan supports in place on the corresponding burners.
Adjusting the gas valves
Turn the control knobs to the lowest setting.
1.
Remove the control knobs from the gas valves. A
2.
flexible rubber sealing ring will be visible. Push down
with the tip of a screwdriver on the gas valve's
setting screw.
Never remove the sealing ring. Sealing rings
prevent liquids and dirt from finding their way into the
appliance and impairing its ability to function properly.
If necessary, use a Torx screwdriver to adjust the
3.
mark
bypass screws:
A: For ULPG the bypass screws must be tightened
50
properly.
B: For Natural Gas the bypass screws must finish
flush with the fitting.
66
87
96
45
Make sure that the flame does not go out and that
there are no flashbacks when you turn the control
knob between the highest and lowest setting.
Never remove the gas tap axle. In the event of damage,
the gas valve must be completely replaced.