If you want to test again, press the power button to restart the
countdown cycle.
The tester will be turned off automatically after Step 6 in
g
15~20 seconds.
The forced power off will be available in Step 3 and Step 4.
g
Press and hold power button for 2~3 seconds to turn tester off.

Important notes:

When you have eaten, drunken alcohol or smoked a cigarette,
wait at least 20 minutes before starting the measurement.
If the test result is below 0.07 per mill then the device shows 0.00
per mill on the display. This happens because at a low range
of alcohol concentration, there is a possibility to measure other
material in your mouth.
Only ths usage of
original ACE mouthpieces
guarantees the accuracy of the test results
g
guarantees 100 % safety of hygiene
g
guarantees full warranty of this device
g
4. When the countdown reaches
zero with a double beep sound,
three dashes will be displayed and
„START" will flash. Blow through
the mouthpiece for five seconds
until there is a double beep sound.
5. When the sampling is successful,
LCD outer lines will be turning
along the edge of LCD as you can
see in the left picture.
6. The estimated BAC (Blood
Alcohol Concentration) will be
displayed after a few seconds
(depending on the alcohol level)
and the readings will flash for
several seconds.
ACE Technik warns:
Even if you get a result with the meaning „Safe range", you
should not drive after having consumed alcohol or do any other
activities which are badly affected by the consumption of alcohol.

Memory mode:

The tester will recall up to 10 test results and their measurement
time.To enter the memory mode, press memory button for about
2 seconds during the countdown (Step 3). The most recent test
result will appear - first the measurement time will be shown (in
three display methods, see below), then the test result will appear
right after the measurement time. To see the next saved test
result (and before its measurement time), just press the memory
button sequentially.
The display method of measurement time:
1. Measured time up to 600 minutes ago will be shown as
"-elapsed time". For example:
Measured 1 minute ago -> -001
Measured 23 minutes ago -> -023
Measured 523 minutes ago -> -523
2. Measured time from 601 minutes ago to 1 day will be shown
as "d000". For example:
Measured between 601 minutes ago and 24 hours ago -> d000
3. Measured time from 1 day ago to 999 days ago will be shown
as "d+ elapsed days". For example:
Measured 1 days ago -> d001
Measured 23 days ago -> d023
Measured 523 days ago -> d523
The tester will recall up to 10 test results with measurement time.
If the memory is full, the oldest test result including measurement
time will be deleted automatically.
Notes to the battery law (BattG):
The device for which this operating manual is contains two AAA
alkaline batteries (1.5 V) in delivery condition. Those batteries are
not made for recharging.
Trying to recharge can cause damage to property or persons.
Also the use of rechargeable batteries is not possible with this
device, because it can cause damage to the device.