Actuonix T16-SS-GG-VV-P Kullanıcı Yapılandırma Kılavuzu - Sayfa 7

Kontrolör Actuonix T16-SS-GG-VV-P için çevrimiçi göz atın veya pdf Kullanıcı Yapılandırma Kılavuzu indirin. Actuonix T16-SS-GG-VV-P 9 sayfaları. Usb control and configuration of the linear actuator control board

Distance
× 1023
Stroke
For example, to set the limits to 1mm from the end stop of a 30mm stroke actuator, set
EXTEND_LIMIT to 34.
1
× 1023= 34
30
0x04 SET_MOVEMENT_THRESHOLD
This value determines the minimum actuator speed that is considered a stall. When the
actuator speed drops below this value, the stall timer begins counting.
0x05 SET_STALL_TIME
This is the amount of time in milliseconds that the actuator will wait before turning off
the motor when a stall is detected. This timer is triggered when the actuator determines
the speed of movement is below an acceptable level. The actuator will exit this state
when the input signal tells the actuator to move in the opposite direction.
0x06 SET_PWM_THRESHOLD
This value sets the distance around the set point where the PWM PD controller is active.
When the distance between the feedback and set point is greater than this value the
actuator speed is set to maximum.
0x07 SET_DERIVATIVE_THRESHOLD
This value is compared to the measured speed to determine when the PWM should be
increased to attempt to exit a stall condition. This is normally set to the same value as the
MOVEMENT_THRESHOLD.
0x08 SET_MAX_DERIVATIVE
This value sets the maximum value that the derivative term can contribute to the control
speed.
0x09 SET_MIN_DERIVATIVE
This is the minimum value that the derivative can contribute to the control speed.
0x0A SET_MAX_PWM_VALUE
This is the value that is manually controlled by the speed potentiometer. This is the
speed that the actuator runs at when outside the PWM_THRESHOLD. Setting this to