SEC TION 5 • PRODUC T SPECIFICATIONS

Measurement Ranges

Temperature
Main Unit: 32ºF to 122ºF / 0ºC to 50ºC
Wireless Sensor: -40ºF to 158ºF / -40ºC to 70ºC
Humidity
Main Unit: 16% to 98% Relative Humidity
Wireless Sensor: 1% to 99% Relative Humidity
Wind Speed
Wireless Sensor: 0 to 100 m.p.h. / 0 to 161 kph

Specifications

Power Requirements
Main Unit: 3 x "AA" alkaline or lithium batteries
Wireless Sensor: 4 x "AA" alkaline or lithium batteries
Wireless Communication 433 MHz Radio Frequency-Transmission every 18 seconds
Set Wireless ID
This wireless thermometer
uses long range 433mhz
radio frequency for
communication.
In the event that you have
reception problems due to
interference, both the main
unit and the wireless sensor
have a selectable wireless ID.
The ID switches are located
within the battery
compartments of the main
unit and the wireless sensor.
You may choose A, B or C; but
both the
main unit and the
wireless sensor ID's must match
for successful synchroniza-
tion.
Atomic Clock
Frequency: WWVB 60Khz
Synchronizes Daily
A
A B C
B
C
Both wireless ID's
must match
- 12 -

Troubleshooting

Problem
Bad
Wireless Sensor
Reception
no bars
Bad
Atomic Clock
Reception
no bars
No Wireless Sensor Data
(no communication)
no bars and flashing
antenna icon
Main Unit
Display Not Working
Please DO NOT return product to the retail store.
For technical assistance and product return information, please call Customer
877-221-1252
Care:
www.chaneyinstrument.com
Possible Solution
Relocate the main unit and/or the wireless
sensor. Both units must be within 100 feet (30
m) from each other. Make sure both units are
placed at least 3 feet (.91 m) from other
electronic appliances and devices that may
interfere with the wireless communication (such
as TV's, microwaves, computers etc). NOTE: It
may take up to 20 minutes for the main unit to
re-synchronize with the sensor when batteries
are replaced. Use lithium batteries in sensor
when temperature is below -4ºF (-20ºC).
Rotate the wireless sensor 90º on its mounting
point. Make certain there are no large stone or
metallic surfaces disrupting the signal line-of-
sight to the state of Colorado. Make sure the
main unit and wireless sensor are placed at least
3 feet (.91 m) from other electronic appliances
and devices that may interfere with the wireless
communication (such as TV's, microwaves,
computers etc). Large metallic surfaces will
interfere with the atomic clock signal.
If wireless reception is bad (no bars), see
"Bad Reception" section above. The wireless
ID setting on each unit must match for all
units to communicate properly. See "Set
Wireless ID" on the previous page.
Make certain that the batteries are installed
correctly and that they are contacting the
terminals. Make certain all contacts are clean.
The batteries may need replacing.
Mon. - Fri. 8:00 A.M. to 4:45 P.M. (CST)
- 13 -