1-1. PRECAUTION ON REPLACING THE SY-258 BOARD
Destination Data
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
USB Serial No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
1-2. PRECAUTION ON REPLACING THE CABINET FRONT
Perform the following procedures for each of the three washers.
Note: Measure the dimensions before replacement of the Cabinet Front according to procedures (1) to (3).
(1) Remove the Imager Block Assy and the IM Adjust Washers (A, B, C).
(2) Measure the dimensions (A) of the removed IM Adjust Washers.
(3) Measure the distance (B) between the surface of the screw hole where the IM Adjust Washers were set and the surface of the E-Mount.
(4) Replace Cabinet Front.
(5) Measure the distance after replacement of the Cabinet Front (B) between the surface of the screw hole where the IM Adjust Washers were set and
the surface of the E-Mount, then compare it with the distance before replacement (B).
If the distance after replacement (B) is shorter than that before replacement (B)
•
Add IM Adjust Washer with the thickness equal to the difference of dimensions to make the distance (B) equal to that before replacement.
If the distance after replacement (B) is longer than that before replacement (B)
•
Replace to the IM Adjust Washer with the thickness equal to the difference of dimensions
(distance before replacement (A+B) - distance after replacement (B)).
(6) After assembly, take a test shot to check if there is any blur at circumference of the image.
NEX-3A/3D/3K/5A/5D/5K/5CK/5H_L2
A6CCCE74558B3E905AD2CEF677F08944E4F80AE9D638E1A7EC0B95815DA1F3ED
1. SERVICE NOTE
– ENGLISH –
1-1. SY-258基板交換時の注意
仕向けデータ
補修用基板と交換する時、補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
USBシリアルNo.
セットは、1台毎に異なる固有のID (USB Serial No.) を書き込んだ後、出荷されています。
新品の補修用基板には、このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
1-2. 前キャビネット交換時の注意
以下の手順は3箇所それぞれ行ってください。
注意: 前キャビネットの交換を行う前に、手順(1)から(3)にて交換前の寸法を測定してください。
(1) イメージャ Assy、IM調整ワッシャ (A, B, C)を取り外してください。
(2) 取り外したIM調整ワッシャの寸法 (A) を測定してください。
(3) IM調整ワッシャが取り付いていたビス穴端面からE-Mount端面までの寸法 (B) を測定してください。
(4) 前キャビネットを交換してください。
(5) 前キャビネット交換後のIM調整ワッシャが取り付いていたビス穴端面からE-Mount端面までの寸法 (B) を測定し、交換前の寸法
(B) と比較してください。
・交換前の寸法 (B) より交換後の寸法 (B) が低かった場合
差分寸法分のIM調整ワッシャを追加し交換前の寸法 (B) と同じ高さにしてください。
・交換前の寸法 (B) より交換後の寸法 (B) が高かった場合
交換前の寸法 (A+B) - 交換後の寸法 (B) を行い、差分寸法分のIM調整ワッシャへ交換してください。
(6) 組立完成後、試し撮りを行い周辺ボケが無いか確認してください。
1-1E