Cisco AS5800 Manuel - Sayfa 6

Sunucu Cisco AS5800 için çevrimiçi göz atın veya pdf Manuel indirin. Cisco AS5800 16 sayfaları. Access server channelized t1/e1 trunk cards
Ayrıca Cisco AS5800 için: Manuel (22 sayfalar)

Cisco AS5800 Manuel
CT3 Trunk Card Overview
Table 3-1
LED
RALM
NLOOP
T3EN
T3LOOP
LOS
AIS
FERF
OOF
1. This LED must be lit for proper CT3 operation.
2. When in loopback mode, enables diagnostics to perform local CT3 testing without external support. The CT3 line is not
3. This LED must remain off for proper CT3 operation.
Trunk Card Connectors
The CT3 front panel is designed with two types of cable connectors (see Figure 3-4). The BNC
connectors are used to connect the cables carrying the T3 signals. The bantam jacks are used for local
BERT circuit testing to the DS1 level.
Cisco AS5800 Universal Access Server Dial Shelf Card Guide
3-6
CT3 Trunk Card LED Indicators (continued)
Color
Description
Yellow
Remote alarm—Lights to indicate a T1 alarm condition was encountered
by software for a particular port; remains OFF when the operating
condition is normal.
Yellow
Network loop—Lights to indicate that at least one T1 is unavailable (status
indicator); remains OFF when the operating condition is normal.
1
Green
Enable—Lights to indicate a CT3 card line connection enabling normal
operation.
2
3
Yellow
Loopback—Lights to indicate that a loopback condition exists on the CT3
line; software controlled.
3
Yellow
Loss-of-signal—Lights to indicate that the CT3 framer is experiencing a
loss of signal (175 successive zeros).
3
Yellow
Alarm indication signal—Lights to indicate the presence of AIS in the
received CT3 line. Lights to indicate that a T3 alarm condition exists;
remains OFF when the operating condition is normal.
3
Yellow
Far-end receive failure—Lights to indicate a far-end receive failure on the
CT3 line.
3
Yellow
Out-of-frame—Lights to indicate an out-of-frame condition on the CT3
line.
affected by this condition, thus remaining disconnected and open.
Chapter 3
Channelized T3 Trunk Card
78-7097-03