Whirlpool UXI6536BSS Kurulum Talimatları ve Kullanım & Bakım Kılavuzu - Sayfa 8
Havalandırma Davlumbazı Whirlpool UXI6536BSS için çevrimiçi göz atın veya pdf Kurulum Talimatları ve Kullanım & Bakım Kılavuzu indirin. Whirlpool UXI6536BSS 32 sayfaları. 36" (91.4 cm) island-mount canopy range hood
Ayrıca Whirlpool UXI6536BSS için: Kurulum Talimatları ve Kullanım ve Bakım Kılavuzu (32 sayfalar)
Assemble Range Hood
1. Install transition on top of hood (if removed for shipping)
with 2 - 3.5 x 9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw (2)
2. Position the 4 vertical supports (A) with the notches
at the bottom and attach to the range hood using
16 - 4.2 x 8 mm screws.
3. Attach the horizontal support (B) using 8 -
4.2 x 8 mm screws.
A
C
A. Vertical supports
B. Horizontal support
C. Notched end
4. Attach a second set of vertical supports (A) and set
the vertical height (B). See "Installation Dimensions"
in the "Location Requirements" section to help
determine the desired dimension for vertical height "B."
Secure with 16 - 4.2 x 8 mm T20
A
A. Vertical supports
B. Vertical height
8
B
A
C
screws.
®
A
B
Install Range Hood
Non-Vented (recirculating) Installation
1. Attach the air deflector to the upper horizontal support
using 2 mounting screws.
B
A
A. Deflector
B. Mounting screws
2. Measure the length of 6" (15.2 cm) duct needed
to connect the transition to the deflector.
NOTE: Vent should fit up inside the deflector
1" (2.5 cm) minimum.
3. Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily remove
the deflector from the chimney support bracket and replace
after vent section is in place.
4. Seal all connections with vent clamps. Continue
with "Range Hood Installation" in this section.
Range Hood Installation
1. Using 2 or more people, lift the range hood assembly
and attach it by snapping the vertical supports to the
spring clips in the upper horizontal support bracket
that is mounted to the ceiling.
NOTE: The range hood assembly must be held in place
while you are installing the screws in the next step.
2. Install 16 - 4.2 x 8 mm screws and tighten to secure.
A
A. Mounting screws
Connect Vent System
1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections
with vent clamps.
3. Use caulk to seal all openings.
B