Arts Energy Smart Module Kullanıcı Kılavuzu - Sayfa 14
Güç Kaynağı Arts Energy Smart Module için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Arts Energy Smart Module 18 sayfaları.

THE BATTERY IS EMPTY BEFORE GAS GAUGE LEVEL
ACTUALLY FALLS TO 0%-10% LEVEL (BLINKING RED)
Possible cause
The autonomy of the battery is reduced
after repeated use of the battery.
This is a normal phenomenon called
ageing.
THE BATTERY SEEMS BLOCKED, PUSH BUTTON AND
CONNECTION OF CHARGER HAVE NO EFFECT
Possible cause
The calculator integrated in the battery
controller is blocked.
The status or gas gauge LED's are not in
a normal status
battery connected to the charger
during storage.
Action
To do a calibration of the gas gauge to
the true capacity of the battery, do a
complete charge of the battery until
the status LED lights up in green.
Then discharge once completely until
blinking of gas gauge low level LED
(0%-10%).
If the shift between gas gauge
capacity and cell capacity is greater
than 10%, it is necessary to do several
calibrations to have accurate gas
gauge indication.
Action
Do a reset as described in the "FAQ"
section (page 12).
14