Bolt Spec and Tightening Procedure
Use four 5/8" bolts and nuts of grade five minimum and suitable washers. There must be a minimum of six threads of
engagement. Use a ring gasket conforming to ASME 16.21. The notch that is cut into the side of the inlet flange is the
front of the monitor (see Figure 2).
Start the bolt tightening procedure by lubricating the nuts and bolts. Hand tighten the nuts until they are snug against
the flange. The final torque of the bolts should be a maximum of 100 lb-ft. Following the correct sequential order as
shown in figure 2, tighten the bolts to 30% of the final torque. Repeat the tightening sequence to 60% of the final
torque. Repeat a third time to 100% of the final torque. Finally, repeat the sequence at the final torque.
FIGURE: 2 - Bolt Torque Order
Rotational Hard Stops
The stainless steel rotational hard stops set the boundaries for the area that the monitor is allowed to travel left
(counterclockwise) and right (clockwise). The stop in the lower row controls the left (CWW) travel, and the stop in the upper
row controls the right (CW) travel. Refer to figure 3 for the locations of the upper row and the lower row, as well as points 1-5.
The monitor is shipped with a stop in the lower row at point 1, which stops the monitor at -170° CCW, and a stop in the
upper row at point 5, which stops the monitor at +170° CW. To set a different boundary area, swap the positions of the
steel hard stop and a plastic plug. Refer to figure 4 to select a desired boundary area. Both the stops and the plugs
have a 1/2" hex head.
FIGURE: 3 - Hard Stop and Plug Locations
#1
HARNESS
JUNCTION BOX
#2
#4
#3
#2
UPPER ROW
LOWER ROW
#3
HARNESS
JUNCTION BOX
Page 6
#5
#4
NOTCH AT
FRONT OF
MONITOR