ASI 0165 Montaj Şablonu - Sayfa 2
Kurutucu ASI 0165 için çevrimiçi göz atın veya pdf Montaj Şablonu indirin. ASI 0165 2 sayfaları.
Recommended mounting heights
- from bottom edge of dryer above finished floor (AFF)
Men
50"
(1270 mm)
Women
47"
(1194 mm)
Children 4-7 years
35"
(889 mm)
Children 8-10 years
39"
(991 mm)
Children 11-13 years
43"
(1092 mm)
Children 14-16 years
47"
(1194 mm)
Handicaped
40"
(1016 mm)
- IMPORTANT - READ COMPLETELY BEFORE
Installation
STARTING INSTALLATION PROCEDURE
1. Make sure power supply breaker is switched off. Installation must be carried out in accordance
with the current edition of the local wiring regulations code having jurisdiction. Installation should
be performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations) and mark
locations of 4 mounting holes and wire service entry at knockout (KO) location.
Note: For two or more dryers, dryers should be no closer than 24 inches (610 mm) on center.
3. Remove and retain 2 cover screws and cover.
4. For in-wall (concealed) power supply - Provide supply wire to KO location according to local code
and attach securely to chassis at KO with appropriate strain relief connector (not supplied).
5. Attach dryer to wall. For wood wall/studs use ¯1/4 inch (6 mm) screws at length that will ensure
1 inch (25 mm) min. stud penetration. For masonry walls use expansion bolts or anchors for ¯1/4 inch
(6 mm) screws to ensure penetration 1/4 inch (6 mm) deeper than anchor. Shim if necessary to
ensure base plate is flat against wall.
6. Connect supply and ground wires to terminal block where indicated or connect supply wires to terminal
block where indicated and connect ground wire to base plate with ground screw (Connections: A.
Connect the live wire (colored Brown or Black) to the terminal block marked "L1". B. Connect the
neutral wire (colored White or Grey) or connect the second live wire (colored Red or Orange) to the
terminal block marked "N/L2". C. Connect the ground wire (colored green or green and yellow or bare
conductor) to the terminal block marked "
" or to the green screw marked "
neutral wires depend on voltage of supply service and requirements of Building and Electrical Code
having jurisdiction.
7. Replace cover. Do not over-tighten screws.
8. Switch on circuit breaker and test unit operation.
9. Complete and mail registration reply postcard.
Reference ADAAG
AFF (maximum)
Reach LIMIT (unrestricted)
All Approaches
48"
(1219 mm)
"). Colors of live and
Schematic
)
( 2 2 0
/ 3 2 "
8 - 2 1
)
2 0 0
8 " (
7 - 7 /
SEE NOTE 6
Circuit Diagram
The ground wire must be connected
0165/0185/0195 100-240VAC
NOTE
to the dryer's backplate.
0184
277VAC
Service by qualified electrician ONLY.
Thermal Switch 25A
Supply line 75 C requirement.
on Heater element
Do not daisy chain the ground wire.
P/N A0013
Connect to 20A branch circuit ONLY.
(Brown)
L1
0165 P/N A0036
(Blue)
0184/0185/0195 P/N A0019
N/L2
SENSOR
(G/Y)
Transistor power switch
40A P/N A0024
1 2 3 4 5
G
1 2 3
CIRCUIT BOARD
100-240VAC-P/N A0009
277VAC-P/N A0038
1 2 3
(Black)
(White)
(Blue)
IMPORTANT
USE TEMPLATE
05072041-1
05072041-2
Rev B 30 Aug 07