NOTE!
4. Install the silicon sealing plugs, marked with a letter A, B and C in the air holes of the
corresponding burners.
If applicable (see table).
Gas
P
ULPG
2.75 kPa
5. Replace the fitted governor by the test point adapter.
6. Place label "Universal LPG" over the label "Natural gas" at the underside of the appliance and
in the cupboard.
Check for gas tightness and operation
When the appliance is connected to the gas supply, use leakage test spray to check the gas
tightness.
A. Check leakage of the installation:
1. Open the main gas valve.
2. Check leakage of connections by spraying leakage test spray on the connections and check
for gas tightness.
B. Check the leakage of the injectors:
1. Seal the injector.
The injector for the outer burner is the one at the bottom, the upper
injector is for the inner burner.
A
a
B
0.46
0.26
0.60
Conversion instruction
b
C
c
H1
0.30
0.72
0.36
0.93
H2
h
Plug
0.40
0.40