American Standard Ellisse 2703.218W Технічна специфікація - Сторінка 2
Переглянути онлайн або завантажити pdf Технічна специфікація для Ванни American Standard Ellisse 2703.218W. American Standard Ellisse 2703.218W 4 сторінки. Built-in whirlpool high gloss acrylic
SEE FITTING
SPECS FOR
19mm
DIMENSION
(3/4)
387mm
(15-1/4)
813mm
(32)
C/L OF
SUPPLIES
51mm
(2)
C/L OF DRAIN
OUTLET
C/L OF
SHOWER ARM
SAFE-T-HEATER
REMOVABLE BLANK
102mm
(4)
305mm
(12) OPT.
TOP
OF
51mm
DECK
(2)
95mm
C/L OF
(3-3/4)
OVERFLOW
546mm
(21-1/2)
INTEGRAL
FEET
ROUGH
1-1/2 N.P.T.
FLOOR
THREADS
1-1/2 O.D.
TAILPIECE
GENERAL SPECIFICATIONS FOR 2703/5 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT 3 )
SYSTEM I PUMP
SYSTEM II PUMP
NOTES:
BATH MUST BE INSTALLED ABOVE THE FLOOR LINE AS BUILT-IN INSTALLATION. SUMP OF BATH IS SUPPORTED BY
INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.
OPTIONAL APRON NO. 9160.2705 & GRAB BAR KIT NO.9827.200 AVAILABLE AND MUST BE ORDERED SEPARATELY.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
LEFT HAND OUTLET SHOWN, RIGHT HAND REVERSE DIMENSIONS 2703.118W/2705.118W.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING
SYSTEM PIPING, DRAIN OVERFLOW, AND APRON INSTALLATION. MOUNTING HOLES DRILLED BY INSTALLER.
ON SYSTEM II: CONTROL MODULE TO BE MOUNTED BEHIND ACCESS PANEL, A MINIMUM OF 152mm (6) ABOVE ROUGH
FLOOR.
Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI
IMPORTANT:
Standard Z124.1.These measurements are subject to change or cancellation. No responsibility is assumed for use of
superseded or voided pages.
ELLISSE BUILT-IN™ WHIRLPOOL
1524mm
(60)
229mm
(9)
FINISHED
WALL LINE
229x305mm
(9x12) FLOOR
CUTOUT
ALT. PUMP
LOCATION
TO PUMP FOR SERVICING
FINISHED WALL
C/L OF
VALVES
C/L OF
WATER
SPOUT
RETENTION
FLANGE
LEVELING
STRINGER
NOT FOR
SUPPORT
ROUGH
FLOOR
38mm
(1-1/2)
60 x 32 x 21-1/2 In. (1524 x 813 x 546mm)
643 Lbs. (292 Kg.)
44-1/2 X 20 In. (1130 mm X 508 mm)
58 X 26-1/4 In. (1473 mm X 667 mm)
14-1/2 In. (368 mm)
48 Lbs./Sq.Ft. (231 Kgs./Sq.m)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
1.6 HP, 9.7 AMPS, 120V.
2.1 HP, 15.6 AMPS, 120V.
© 2003 American Standard Inc.
HIGH GLOSS ACRYLIC
WATER RETENTION
FLANGE (3) SIDES
PUMP
ON/OFF SWITCH
PROVIDE ACCESS
ON ALL INSTALLATIONS
1651-1981mm
(65-78)
OPTIONAL
38mm
(1-1/2)
UNDERSIDE
OF DECK
533mm
(21)
83mm
(3-1/4)
141 Lbs. (63 Kg.)
60 Gal. (277 L)
50 Gal. (189 L)
20.8