INSTALLATION OF LIGHT (FIBREGLASS)
1. Locate position in pool that lights are to be mounted. The fitting should be performed to position the light
approximately 300mm below the water level of the pool during normal operation. Do not install lower than
430mm below pool edge otherwise cable will not be sufficient to bring light up to pool deck for lamp
replacement.
2. Using a hole saw, cut 60mm diameter hole at the light location. Once cut, clean hole to ensure no debris
or burrs are remaining.
3. Fit CalidoRay light through hole in pool shell ensuring rubber seal is on the water side of the pool shell.
Run a line of silicon around the hole on the outside of the pool shell then tighten nut up onto the thread of
the light body.
4. The light transformer has an IP44 rating which allows installation in Zone 2 of the pool area (a minimum of
2m from the waters edge). The transformer should be installed in a suitable position at least 1.2m above
ground level and in accordance with all local, state and national wiring standards.
5. Connect cable from light to light transformer. The transformer is not polarity sensitive and either wire can
be connected to either terminal.
Inst294 CalidoRay Underwater Lights V12.11
3