Astralpool CalidoRay Інструкція з монтажу та обслуговування - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з монтажу та обслуговування для Підводне освітлення Astralpool CalidoRay. Astralpool CalidoRay 6 сторінок.
INSTALLATION OF LIGHT (CONCRETE)
1. Locate position in pool that lights are to be mounted. The fitting should be performed to position the light
approximately 300mm below the water level of the pool during normal operation. Do not install lower than
430mm below pool edge otherwise cable will not be sufficient to bring light up to pool deck for lamp
replacement.
2. Fit CalidoRay concrete wall conduit into steel work marking sure it is secure and will not move during
concrete pour. Ensure cap is fitted to conduit prior to concreting. Note: There are indicators on the side
of the conduit to guide depth inside the wall. It is important to have a minimum of 180mm from the
rear of the conduit to the front of the pool wall.
3. After concrete pour cut conduit flush to pool surface.
4. Fit light into wall conduit and glue into place prior to commencing pool surface finish.
5. The light transformer has an IP44 rating which allows installation in Zone 2 of the pool area (a minimum of
2m from the waters edge). The transformer should be installed in a suitable position at least 1.2m above
ground level and in accordance with all local, state and national wiring standards.
6. Connect cable from light to light transformer. The transformer is not polarity sensitive and either wire can
be connected to either terminal.
REPLACEMENT OF LAMP (LED OR XENON)
1. Remove clip on lens from front of CalidoRay light. Grip front of light and turn in anti-clockwise direction to
remove light from the housing. Bring light up to above water level.
2. Undo screws from flexible lens ring and remove lens and ring.
3. Replace lamp ensuring no moisture is present inside the housing. It is important to replace the o'ring seal
each time the light housing is opened.
4. Replace lens and ring on front of light and tighten screws. (Ensure o'ring remains in place)
5. Feed cable back into light housing and tighten body into place by turning in a clockwise direction.
Inst294 CalidoRay Underwater Lights V12.11
4