AIR GUARD AG-20 Посібник користувача - Сторінка 7
Переглянути онлайн або завантажити pdf Посібник користувача для Випарники AIR GUARD AG-20. AIR GUARD AG-20 13 сторінок. Antibacterial vaporizer
Operation
Manual Mode
Put DIP switch 1 ~ 9 to OFF position for manual mode.
In the manual mode, fog output can be triggered by either keeping holding the handle button or
pressing once the button A on the wireless transmitter. To stop fogging, release the handle button
or press once the button B on the wireless transmitter.
Timer Mode
Use the DIP switch located in front of machine to set the timer's duration (fogging) time. Duration
time can be set from 15 to 240 seconds. Put DIP switch to ON position for desired duration time.
Longer timer setting overwrites shorter timer setting. For example: When both DIP switch 1 and 9
set to ON position, the duration time will be 240 seconds.
Timed fogging can be triggered by either pressing the handle button once or pressing the button A
on the wireless transmitter once. When the timed fogging's time is up, machine stops automatically.
To stop timed fogging immediately, press once handle button or press once the button B on the
wireless transmmiter.
Radio Wireless Remote System
Radio wireless remote control system consists of a transmitter with two buttons to activate and
deactivate fogging. The wireless signal receiver (antenna) is attached to the rear panel of AG-20.
W-1 Wireless Transmitter
7