Electrolux AOFP101U Посібник - Сторінка 10

Переглянути онлайн або завантажити pdf Посібник для Морозильна камера Electrolux AOFP101U. Electrolux AOFP101U 11 сторінок. Bcf 30kg 6 gn1/1 lw (240/3/60hz), bcf 50kg 10 gn1/1 lw (240/3/60hz) / bcf 100kg 20 gn1/1 lw (240/3/60hz) / bcf 70kg 10 gn2/1 lw (240/3/60hz) / bcf 180kg 20 gn2/1 lw (240/3/60hz) / bcf 30kg 6 gn1/1 lw (208/3/60hz) / bcf 50kg 10 gn1/1 lw (208/3/60hz) / bcf
Також для Electrolux AOFP101U: Посібник з експлуатації та технічного обслуговування (27 сторінок)

Electrolux AOFP101U Посібник
It is advisable to use a floor grate.
For AOFP061U, AOFP101U and AOFP102U appliances, the
drain diameter is 1½", therefore it is advisable to use a 1½" drain
hose.
For AOFP201RU appliances, the drain diameter is ¾", therefore
it is advisable to use a ¾" drain hose.
The drainage course to the open drain must be fitted with a trap,
to prevent any backflow from the sewage network reaching the
internal pipes in the appliance. Make sure there are no kinks in
the hosing or elbows in the metal pipes in the drainage course.
Avoid horizontal stretches, where water may collect and stagna-
te.
Note: before removing the drain plug to drain off the chamber,
make sure the appliance has been connected to a drain trap
system, or that the drain tray has been emptied.
This equipment is to be installed to comply with the applicable
Federal, State or local plumbing codes.
B.1.5 POSITIONING APPLIANCES ARRANGED FOR USE
WITH REMOTE UNITS AND POSITIONING OF CONDENSING
UNITS
7
Important: the operation must be carried out by professionally
qualified personnel.
Install the unit following all safety measures required for this
type of operation.
Place the condenser unit in a well-ventilated room a long way
from heat sources.
If the remote unit is to be installed outdoors, it must be protected
against natural elements with a cover, which must not impair the
ventilation of the condenser unit.
The pipe cross-section must comply with the specifications in
the technical data:
-5
-5
8
See also the drawing here below:
18
CAUTION:
RECOMMENDED COOLING UNIT SPECIFICATIONS
FOR CUSTOMER SUPPLIED COMPRESSOR
Refrigerant power HMBP [W]
condensation temp. at 113°F/+45°C
evaporation temp. at 23°F/-5°C
suction gas temp. at 68°F/20°C
without liquid subcooling
Refrigerant power HMBP [W]
condensation temp. at 113°F/+45°C
evaporation temp. at -4°F/-20°C
suction gas temp. 68°F/20°C
without liquid subcooling
Refrigerant power HMBP [W]
condensation temp. 113°F/+45°C
evaporation temp. at -22°F/-30°C
suction gas temp. at 68°F/20°C
without liquid subcooling
A
B
17000
9050
5570
A
B