Andersen Eagle VeriLock 13725 Посібник користувача - Сторінка 15

Переглянути онлайн або завантажити pdf Посібник користувача для Аксесуари Andersen Eagle VeriLock 13725. Andersen Eagle VeriLock 13725 15 сторінок.

Appendix A:
The following is a general guideline for enrolling the Verilock sensors to the control panel. Please consult the control
panel manufacturer for specific panel model detailed instructions.
1. Access the "Tools" or "Programming" section of the control key pad.
2. Enter the installer code to access the programming menu (this information may be manufacturer and
panel model specific).
3. Select the program mode.
4. Program the zone.
a. Select the "zones" option.
b. Select the next available zone.
c. Access edit mode and enter the serial number ID found on the Verilock sensor battery slip strip.
5. Program the loop.
a. "1" for Open/Close
b. "2" for Lock/Unlock
• Note: You cannot program the same serial number ID & Loop combination twice.
c. Select the "Zone Descriptor 1" field and type in a description and select "Save".
• If the zone is Loop 1 (Open/Close), recommend using "Open" or "Opening" for Zone Descriptor 1.
• If the zone is Loop 2 (Lock/Unlock), recommend using "Unlocked" or "Lock" for Zone Descriptor 2.
d. Select the "Zone Descriptor 2" field, type in a description and select "Save".
• This field should be used to describe the window or door: "Left Casement" or "Kitchen 1". Most key
pads display 8-10 characters.
6. Program the zone type and chime.
a. Select the "Zone Type" field and change to either "Window" or "Door", as appropriate.
b. Select the "Chime" field and change to "Yes". (Optional).
7. Select "Save" to complete the programming for a zone.
Note: The above steps will need to be repeated twice for each window or door sensor to enroll both open/close and
lock/unlock detecting.
9125921 BB
Revised 07/28/14
15
User's Guide