below). The Limit control allows you to set your level for clean tones and keep the
same level for higher volume settings such as solos.
8. REVERB MIX CONTROL –
to the dry signal. Use in conjunction with the reverb (Limit) control (see above).
On many amps, this control is labeled simply "reverb". Turning the control
clockwise increases the volume of the reverb signal as it mixes with the dry signal.
9. STANDBY SWITCH –
your amp is equipped with an optional solid state rectifier, observe the instructions
below *. If equipped with the standard tube rectifier, it is not necessary to start the
amp in the standby mode. However, it is a good idea to place the amp in standby
when taking a break to extend the life of the tubes and to allow the amp to cool.
*If equipped with a solid state rectifier: When turning on the amp, make sure
the STANDBY switch is in the off (down) position. Turn on the POWER (up
position) switch first. The pilot light will light up. Wait at least one minute to allow
time for the tubes to warm up completely before turning on the STANDBY switch.
After the tubes are warmed up, turn on the STANDBY switch (UP position) to
operate the amp.
10.
POWER SWITCH
Always turn off the POWER switch when not using the amp for a couple of hours
or more.
11.
PILOT LIGHT
bulb replacement, simply unscrew the red lens, grab the bulb with your fingers,
push in while turning counterclockwise and release. Replace with a standard #47
bulb. The lens thread fits many standard lamp lenses and "jewels" allowing you to
customize the color if you desire.
For adjusting the mix of reverb signal compared
This switch turns on the high voltage for the tubes. If
– This switch turns on the main power to the amplifier.
– This light indicates when the main power is turned on. For
7