Atlantic Ultraviolet SANITAIRE RSM2680 Експлуатація та технічне обслуговування установки - Сторінка 13

Переглянути онлайн або завантажити pdf Експлуатація та технічне обслуговування установки для Аксесуари Atlantic Ultraviolet SANITAIRE RSM2680. Atlantic Ultraviolet SANITAIRE RSM2680 16 сторінок. Germicidal ultraviolet room air sanitizers

i
f
ntaKe

ilter

These filters require regular replacement and should be replaced when the Filter Replacement Indicators, located on the
front monitor display changes from glowing GREEN to YELLOW or RED (Flashing).
The SANITAIRE
Germicidal Ultraviolet Room Air Sanitizers are fitted with (4) Synthetic Pleated (MERV 7) Filters.
®
Disconnect power to the SANITAIRE
Turn the two white plastic latches on each of the top corners of the lower filter grill and allow the grill to pivot out to expose
the filter behind the grill. Once the filter is exposed, slide it
from its location. (See "Filter Replacement" on Page 10)
Once the filter is removed, use a vacuum to remove any
trapped dust or dirt in and along the filter frame.
Be careful not to damage the protective
mesh located in the back of the filter frame. Contact factory
if this mesh is ever damaged or appears to need replacement
(See Figure 14).
Position the replacement filter so that the arrows on the
filter showing the flow direction face inwards to the unit
and slide the filter into the frame. (See Figure 12 in "Filter
Replacement" Section on Page 10)
Once the filter is in place, pivot the filter grill back into
place and rotate the two white plastic latches securing the
filter in place.
B

reaKage

Broken Quartz is SHARP.
Wear protective gloves when handling broken ultraviolet lamps. In the event of breakage,
DO NOT use a household vacuum cleaner to pick up quartz fragments. Sweep up debris into
a plastic bag and dispose of properly
d
m
isPosal of
erCury
Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added
lamps should not be placed in the trash. Dispose of properly. For further information regarding the disposal and
recycling of lamps containing mercury, along with Federal and State requirements visit LampRecycle.org. For more
information on STER-L-RAY

OPTIONAL ACCESSORIES

Zenith™ Germicidal Ultraviolet Detector (30-1015): A sensitive, hand-held, self-contained battery operated ultraviolet
1.
meter that can be used for:
• Monitoring UV-C Germicidal Lamp Intensity & Aging
• Measuring UV-C Germicidal Fixture Leakage
2.
Promate
Safety Glasses (00-1299): Safety eyewear MUST be used as general-purpose safety protection and for
TM
additional shielding from ultraviolet rays.
Promate
Face Shield (00-0126): Lightweight visor with adjustable headgear provides eye and face protection from
3.
TM
germicidal ultraviolet rays.
For more information and purchasing contact our offices, weekdays between 8:30 am and 5:00 pm Eastern time, at:
Atlantic Ultraviolet Corporation
Tel: (631) 273-0500 • Fax: (631) 273-0771 • Email: [email protected] • Website: Ultraviolet.com – BuyUltraviolet.com
.
®
.
a
l
dded
amPs
Germicidal Ultraviolet Lamps, visit Ultraviolet.com or BuyUltraviolet.com.
®
, 375 Marcus Boulevard, Hauppauge, New York, 11788
®
Figure 14