Anywire ASLINK BL296SB-04FS-4A-20 Посібник з експлуатації - Сторінка 13

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Сенсорні термінали Anywire ASLINK BL296SB-04FS-4A-20. Anywire ASLINK BL296SB-04FS-4A-20 15 сторінок.

4-wire (isolated) PNP input
BL296SB-04FS-4A-20
BL296XB-04FS-4A-20 (Input)
<Circuit conditions>
Rated input voltage:
24V DC
Max. switching current:
3.5mA
ON current:
2.2mA or more
OFF current:
1mA or less
ON voltage:
16V or more (IN-0V)
OFF voltage:
8V or less (IN-0V)
Allowable current at 24V:
1A max. (24V-0V)
(per terminal)
CAUTION
To connect loads (e.g. I/O ports) that
are controlled with a power supply
other than the one used for the
AnyWireASLINK system, always use a
4-wire (isolated) terminal.
Otherwise, malfunction may be caused.
[E.g.]
Use the device by connecting the 0V
lines together.
4-wire (isolated) PNP output
BL296PB-04FS-4A-20
BL296XB-04FS-4A-20 (Output)
<Circuit conditions>
Withstand voltage:
30V DC
Max. ON current:
100mA
CAUTION
To connect loads (e.g. I/O ports) that
are controlled with a power supply
other than the one used for the
AnyWireASLINK system, always use a
4-wire (isolated) terminal.
Otherwise, malfunction may be caused.
[E.g.]
Use the device by connecting the 0V
lines together.
24V (Green)
DP (Red)
DN (Black)
0V (White)
24V (Green)
DP (Red)
DN (Black)
0V (White)
4-wire (isolated) ASLINK terminal
(Power supply of the AnyWire system)
24V (Green)
DP (Red)
DN (Black)
0V (White)
24V (Green)
DP (Red)
DN (Black)
0V (White)
4-wire (isolated) ASLINK terminal
(Power supply of the AnyWire system)
-BL296*B04F*4A20 13/15-
24V (1)
Switch, sensor, etc.
(2-wire type)
6.8k
IN (4)
0V (3)
24V (1)
24V
6.8k
OUT
IN (4)
0V (3)
0V
Load driven by
an external power supply
To connect
inductive load, use
OUT (4)
a surge killer.
If output is turned
ON with the OUT
and 0V terminals
short-circuited,
the output device
0V (3)
will be damaged.
24V
OUT (4)
IN
0V
0V (3)
Load driven by
an external power supply