Anywire AnyWireASLINK BS-K5217-M30-1K Посібник з експлуатації - Сторінка 8

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Аксесуари Anywire AnyWireASLINK BS-K5217-M30-1K. Anywire AnyWireASLINK BS-K5217-M30-1K 9 сторінок. Aslink sensor

[Troubleshooting]
If the following statuses of the LEDs are indicated on the
ASLINKSENSOR, take the following actions.
LINK
IN
ALM
Unlit
Unlit
Unlit
Lit
Unlit
Unlit
Unlit
Flashing
Flashing
(alternates
(alternates
with a 0.5 sec
with a 0.5 sec
interval)
interval)
Flashing
(Lit for 0.2
sec, unlit for
1.0 sec)
Flashing
Lit
Flashing
Flashing
(alternates
with a 0.1 sec
interval)
If the following error is indicated on the Address Writer, take the
following action.
Display
Cause
The parameter setting is
【E-0303】
incorrect.
Should any of the following apply, take the following actions.
Symptom
Detection cannot
- Is the metal piece to be detected in an appropriate position?
be made
Adjust the position of metal piece so that it will be in an
appropriate range from the detection face of
ASLINKSENSOR.
- Is the wiring correct?
Ensure that the ASLINKSENSOR transmission line is
connected to the AnyWireASLINK system transmission line
(DP, DN) properly.
- Is there a power supply with a capacity appropriate for the
AnyWireASLINK master and slave units and turned ON?
Check the power supply.
- Has teaching been performed?
Perform teaching using the workpiece to be detected in the
operation.
- Is the sensor used in the speci ed detection range?
Use it within its rating.
Setting cannot be
- Is the wiring correct?
made with the
Check the connection of ASLINKSENSOR transmission
Address Writer
 
line once more.
- Is the power supplied to the AnyWireASLINK system?
Check the power supply.
- Are the parameters set correctly?
Check the parameters and correct them accordingly.
[Parameter and Setting Items]
Parameters
Variable
0-100%
The threshold of sensing level to
【01.】
determine if a detection is made
Threshold
0-100%
The change in the sensing level required
【02.】
Hysteresis
for the detection status to change from
ON to OFF
0-100%
The upper limit for alarm determination
【03.】
Alarm Hi
0-100%
The lower limit for alarm determination
【04.】
Alarm Lo
3-255
The monitoring time for alarm
【05.】
determination (1=100ms)
Alarm
monitoring time
【06.】
0
Normally open
NO/NC
1
Normally closed
【07.】
0
OFF
Alarm feature
1
ON
【10.】
0
Delay timer disabled
Delay timer
1
ON delay timer
ON/OFF
2
OFF delay timer
3
ON/OFF delay timer
0-255
The delay for the delay timers
【11.】
(1=100ms)
Delay
Cause
Remedy
- The ASLINKSENSOR
- Check if there is a disconnection
is not connected to
between the ASLINKSENSOR and
the AnyWireASLINK
AnyWireASLINK system and, if there
system.
was a disconnection, restore the
connection.
- The AnyWireASLINK
system is not turned
- Check the power supply of
on.
AnyWireASLINK system and turn ON
the power.
- Connected directly to
- Reconnect the power to the
the 24-0V power supply.
AnyWireASLINK system.
- The address of
- Assign an address other than 255.
ASLINKSENSOR
remains as "255"
(factory setting).
- The address of
- Look for a unit that has the same error
ASLINKSENSOR is
and assign an address different from
duplicated.
the address of that unit.
- The transmission
- Reduce the number of units connected
signal level is
to the same AnyWireASLINK system.
detected low.
- Reduce the length of transmission line
between ASLINKSENSOR and the
master unit.
- The sensing level is
- Check the condition of
low.
ASLINKSENSOR, adjust its position
and clean the detection face.
- Teaching has not
- Perform the teaching operation again.
been performed
properly.
Remedy
Check the parameters and correct
them accordingly.
Remedy
Description
[Specifications]
■General Speci cations
Ambient temperature/humidity use
Ambient temperature/humidity storage
Atmosphere use
Altitude use*
Pollution level*
*1 Do not use or store AnyWireASLINK devices in an environment where the pressure exceeds
the atmospheric pressure at an altitude of 0 meters. Doing so may result in malfunction.
*2 "Pollution level" is an index that indicates the degree of occurrence of conductive substances
in the environment where the device is used.
Pollution level 2 means the occurrence of only pollution by non-conductive substances.
In such an environment, however, electrical conduction could occur due to accidental condensation.
■Transmission Speci cations
Service power supply
voltage
Transmission method
Synchronization method
Transmission procedure
Connection mode
Number of connection
points
Number of units that can
be connected
RAS features
■Individual Speci cations
Occupied number of points
Current consumption
Detection target *
Standard detection substance
Detection distance
(at the ambient temperature of 23°C)
Stable detection distance
Hysteresis
Response time *
In uence of temperature
In uence of voltage
Protection class
Weight (Main unit, cable)
Weight (Nut)
*
3 The detection distance varies depending on the material.
*
4 The time from detecting the ON or OFF condition until the transmission signal is sent.
This time plus two transmission cycles will be the transmission delay.
<Ambient atmosphere>
Avoid using the device with splashes of water, oil or chemicals on it or in an
atmosphere causing condensation as those fluids may be recognized as
detection targets and leading to erroneous detections.
Factory
The device is especially sensitive to dielectrics and can be influenced by
setting
even a tiny drop of water.
M18: 5
M30: 6
<Influence of surrounding metals>
If the device is to be mounted in a metal body, ensure the distances listed in
5
the table below.
Also ensure the distances shown on this table for installations in materials
other than metals (such as resin) could have an influence on the detection.
80
l
M18: 6
M30: 7
50
0
0
*
5 If the metal body is not grounded, the operation may be unstable. Always ground it.
0
BS-K5217-M18-1K
0
BS-K5217-M30-1K
-BSK5217M**1K 8/9-
-10 – 60°C, 10 – 90%RH No condensation
-25 – 75°C, 10 – 90%RH No condensation
No corrosive gas
0 – 2000m
1
2 or less
2
24V DC +15% to -10% (21.6 to 27.6V DC) with a ripple of
0.5Vp-p or less
DC power supply superimposed total frame/cyclic method
Frame/bit synchronization method
Dedicated protocol
Bus type (Multi-drop method, T-branch method,
Tree branch method)
512 max. (IN: 256, OUT: 256)
Up to 128 units
Detection of transmission line disconnection, detection of
transmission line short circuit, detection of transmission power
drop, detection of duplicated/unregistered ID
1 input point
Supplied by the AnyWireASLINK transmission signal (DP, DN)
M18: 7.5mA
3
Conductors/dielectrics
A grounded metal piece of 50 × 50 × 1mm
M18: 8mm(max.)
M18: 0 – 6.4mm
Depends on the parameter setting
10ms max.
4
The detection distance at 23°C
M18: Within ±20%
Within ±1% of detection distance in the range of 27.6 to 21.6V
power supply voltage for the AnyWireASLINK master unit.
IP67
M18: Approx. 38g
M18: Approx. 2g
φd
Metal body
*
5
l
d
15
40
10
60
M30: 7.6mA
M30: 15mm(max.)
M30: 0 – 12mm
M30: Within ±20%
M30: Approx. 64g
M30: Approx. 3g
m
n
(Unit: mm)
m
n
10
60
20
60