LED
Status
Description
The power connection is operating
ON
normally.
PWR
The power is not connected or is
OFF
not working properly.
The copper port has established
ON
an active network connection.
The copper port is in a network
LINK
Blinking
activity state.
The copper port does not establish
OFF
an active network connection.
The serial port is not sending data
OFF
or sending abnormally
TX(1-2)
The serial port is sending data
Blinking
The serial port is not receiving data
OFF
RX(1-2)
or receiving data abnormally
Blinking
The serial port is receiving data
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
Step 1
Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually accessed.
Step 2
Enter device's IP address in the address bar of the
computer browser.
Step 3
Enter device's username and password in the login
window as shown below.
Click "OK" button to login to the WEB interface of
Step 4
the device.
Note:
The default IP address of the device is "192.168.1.254".
The default username and password of the device is
"admin".
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
100M copper port
10/100Base-T(X)
RJ45 port
Serial port
RS-232 RJ45 port or RS-485/422
terminal
Indicator
Power indicator, network Link/Act
indicator, serial port transmission
and receiving data indicator
Power supply
Input power supply
Access terminal
Consumption
Model I
Model II
Working
environment
Working temperature
Storage temperature
Working humidity
Protection grade
self-adaptive
9~48VDC
2-pin 5.08mm terminal
No-load: 0.79W@9VDC
Full-load: 0.86W@9VDC
No-load: 0.90W@9VDC
Full-load: 1.25W@9VDC
-40~75℃
-40~85℃
5%~95% (non-condensing)
IP40 (metal shell)