The sequence is keyed through the AR3030 numeric keypad:
[4] [8] [0] [0] [ENT] for 4800 bps operation
[9] [6] [0] [0] [ENT] for 9600 bps operation
To restore normal "local" operation to the AR3030 either key in the
sequence Q [CR] via the RS232 or switch the AR3030 Off, wait for 5
seconds then switch On again.
AOR (UK) LTD
or
[3030-NTE revision 5]
AR3030 General Coverage Receiver addendum
Please note the following points regarding
the AR3030 receiver:
1. Microprocessor reset.
There is a 'small' chance that the receiver will not power up
correctly when switched on for the first time. This is due to
the buildup of a static charge during transit from the
packaging etc. Should this occur, simply switch the set off,
disconnect the power supply and leave for a few minutes.
Reconnect and test. Should a problem still persist, please
refer to page 46/47 section (9) of the operating manual.
N.B. An additional SOFTWARE FULL RESET is available
by depressing the [ENT] key (either of the mode keys on some
production units) while switching the receiver On. Hold in the [ENT]
key while all the LCD segments appear and keep it depressed until
the set returns to 10.000 MHz, only then release the key, this will
ensure a "full" reset. This may be useful should the standard reset not
appear to "fully" reset the unit.
See the later note regarding the SSB filter option (if fitted).
2. Optional Collins 2.5 kHz SSB filter (USB/LSB/FAX).
Should you wish to fit the optional SSB filter it MUST be fitted in the
standard SSB filter position replacing the Murata 2.4 kHz filter, it
CANNOT be fitted in the CW narrow position (page 13 section 5-8 of
the operating manual). Nor is it possible to fit an additional AM filter
in the CW narrow position.
!