DIS
Technical Specifications
Unit Specification
Power consumption ......................................................... max. 600W
General
In-rush current .............. max. 30A @115V or max. 60A@230V
Mains voltage: ............................................... 100 - 240V, 50 - 60Hz
Supply voltage for units (each A1, A2, B1, B2)....... 48V/125W
Max. power load on Loop Through connectors ................. 7.5W
Temperature to guarantee specified performance
................................... 5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
............................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight ............................................................................................... 5.5 kg
Dimensions (W x H x D) ......... 425 (483) x 87 x 317 (357) mm
dimensions in bracket are including 19" brackets
DCS-LAN loop through ................................................ 2 pieces RJ45
Connectors
DCS-LAN repeated output ......................................... 4 pieces RJ45
Cable type (min. specification) ....... Cat5e, AWG 24, screened
Cabling and System Limits
Maximum cable length in one chain .................................... 200 m
Working condition ........................................... Fixed, stationary or
System Environmental Conditions
18
To guarantee specified performance ...... 5 Deg C. to 40 Deg C.
Temperature range
Storage temperature .................................. -20 Deg C. to 60 Deg C
Maximum relative humidity .................................................. < 80%
EMC emission
Approvals
EMC immunity
EMC approvals
ESD
Mains harmonics
Environmental requirements ..................... Contains no banned
substances as specified in UAT-0480/100 (e.g. no cadmium
or asbestos)
Accessories supplied .................................................. User manual
.................................................................................................. Mains cable
.................................................................... 5 pieces termination plugs
transportable
Specifications are subject to change without notice
User Manual EX 6010 rev F.doc
User Manual
According
to
harmonized
standard EN 55103-1 and
FCC rules part 15, complying
with the limits for a class A
digital devices
According
to
harmonized
standard EN 55103-2
Affixed with the CE mark
According
to
harmonized
standard EN 55103-2
According
to
harmonized
standard EN 55103-1