A sensor has failed or
General Fault
some other fault has
occurred
The CO cell has
reached the end of its
useable life or a fault
CO Fault
has occurred with
the CO detection
portion of the
detector
The detector has
been operational for
End Of Life
10 years and must be
replaced
The detector may no
longer alarm within
Sensitivity
the smoke sensitivity
Drift/Dirty
limits on the back of
Fault
the device and must
be cleaned
The batteries are low
Low Battery
and must be replaced
Fire test button
Fire Test
pressed and held to
initiate test
CO test button
CO Test
pressed and held to
initiate test
1 YELLOW
flash
Chirp every 48 seconds
every 4
seconds
2 YELLOW
flashes
Chirp every 48 seconds
every 8
seconds
5 YELLOW
flashes
Chirp every 48 seconds
every 12
seconds
1 YELLOW
flash
Chirp every 48 seconds
every 8
seconds
1 YELLOW
Chirp every 48 seconds
flash
(press either button to
every 12
silence for 12 hours)
seconds
3 RED flashes
Temporal-3
in time with
BEEP-BEEP-BEEP-pause
sounder
4 RED flashes
Temporal-4
in time with
PIP-PIP-PIP-PIP-long
sounder
pause
The detector has
Tamper
been removed from
the base
The detector has had
Power Up
batteries installed
and is powered up
The detector is
Normal
operating normally
Operation
with no fault or
alarm conditions
Table 1 - Detector Status LED & Sounder Operating Modes
4.2 DETECTOR DIRTY FEATURE
When the detector has been contaminated and may no longer be within the
marked sensitivity limits the detector will chirp every 48 seconds and flash the
YELLOW LED once every 8 seconds. Refer to Section 10.1 for cleaning your
detector.
4.3 DETECTOR END OF LIFE
When the detector has reached the end of its 10 year operating life it will chirp
every 48 seconds and flash the YELLOW LED 5 times every 12 seconds. The
detector must be replaced.

4.4 LOW BATTERY DETECTION

The detector regularly checks the battery condition. If a low battery is detected the
detector will chirp every 48 seconds and flash the YELLOW LED once every 8
seconds. The chirp may be silenced for 12 hours by pressing either button (See
Section 2.1 Figure 1). The batteries must be replaced using 2 Panasonic CR123A
batteries or 2 Energizer EL123AP batteries.
1 YELLOW
flash followed
by
None
1 GREEN flash
every 12
seconds
1 RED flash
followed by
1 YELLOW
A single chirp
flash followed
by
1 GREEN flash
1 GREEN flash
every 12
None
seconds