Austro Flamm Dexter 2.0 L Інструкція з експлуатації - Сторінка 7

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Піч Austro Flamm Dexter 2.0 L. Austro Flamm Dexter 2.0 L 11 сторінок.

english
WARNINGS:
A wood burning heater is, by its nature, an appliance that operates at high temperatures, so it is necessary to take into account potential risk factors that
should be avoided at all costs. Children must be kept away from any combustion appliance and supervised in the room at all times.
Installation must be carried out by a licenced and certified installer.
The installation must meet the requirements of the manufacturers instructions, AS2918 and the Building Code of Australia.
The appliance must be installed in such a way as to allow easy maintenance.
Incorrect installation may cause serious damage to the equipment and the safety of people and property.
Before installing your appliance, please ensure the following:
The appliance must be installed on a heat resistant surface to 600°C.
o
o
The floor must be structurally sound, to support the installation weight.
o
The compartment below the heater should not be used to store combustible materials (NM-RS models).
Replacement outside air must be supplied to the room with the heater, a minimum equivalent to half the cross-sectional area of the flue, ie 160cm2 free
o
air.
Follow the clearances to combustible materials as shown on page 9. and 10.
o
o
Your appliance must be non-permanently installed and easily accessible to ensure general maintenance (chimney and equipment).
o
The equipment must not be cemented in its enclosure under any circumstances.
Keep these instructions for future reference
WARNINGS:
o
REFER TO COMPLIANCE LABEL – DISREGARD ANY CONTRADICTORY FUEL TYPE INFORMATION IN INSTRUCTION MANUAL
WARNING: THE APPLIANCE & FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918:2001 AND THE APPROPRIATE
o
REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES.
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS
o
4013:2014 WHERE REQUIRED BY THE REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE
PLATE WITH THE MARKING "TESTED TO AS/NZS 4013:2014".
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO
o
BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013:2014.
WARNINGS:
o
CAUTION: MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF
COMPONENETS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST
INSTANCE.
o
CAUTION: CRACKED AND BROKEN COMPONENTS, e.g. GLASS PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION UNSAFE.
o
WARNING: ANY MODIFICATION OF THE APPLICANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING
AS/NZS 4013.
o
WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE.
o
WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING.
o
WARNING: DO NOT STORE FUEL WITHIN THE HEATER INSTALLATION CLEARANCES.
o
WARNING: WHEN OPERATING THIS APPLIANCE AS AN OPEN FIRE USE A FIRE SCREEN.
WARNING: OPEN AIR CONTROL (AND DAMPER WHEN FITTED) BEFORE OPENING FIRING DOOR.
o
o
CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS.
o
THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS.
o
THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE HAZARDOUS.
o
THE APPLIANCE OR FLUE SYSTEM SHOULD NOT BE MODIFIED IN ANY WAY WITHOUT THE WRITTEN APPROVAL OF THE MANUFACTURER.
o
BURN ONLY HARDWOOD
o
Prior to installation check with your state and local authorities regarding any specific regulations that may apply.
9
Dexter