Autonics MX4W Series Посібник з експлуатації - Сторінка 2
Переглянути онлайн або завантажити pdf Посібник з експлуатації для Вимірювальні прилади Autonics MX4W Series. Autonics MX4W Series 6 сторінок. Lcd multi panel meters
Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics webstie.
MX
4
W
-
❶
-
❶ Input type
V: DC / AC voltage
A: DC / AC current
Product Components
• Product
• Bracket × 2
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
91.5
96
■ Bracket
■ Panel cut-out
4.9
36
3
■ Terminal cover
93.7
Cautions during Wiring
• Unit: mm, Use terminals of size specified
below.
≥3.0
≤6.0
F
❷
❷ Preset output
N: Indicator
1: NPN open collector
2: PNP open collector
• Instruction manual
• Terminal cover × 1
4 20
≥ 116
92
+0.8
0
15.9
• Input and output are insulated from the
power.
Option output
ADC input
and
circuit and
hold / zero
display part
1
2
3
4
5
6
7
Connections
■ Input
• For using DC power, connect wires regardless of polarity.
• Indicator model does not have the hold / zero terminal.
HOLD / ZERO
1
2
3
4
MX4W-V-F□
± 500 mVDCᜡ / ± 200 mVDCᜡ /
DC
± 50 mVDCᜡ
①
0 - 500 mVACᜠ / 0 - 200 mVACᜠ /
AC
0 - 50 mVACᜠ
± 20 VDCᜡ / ± 5 VDCᜡ / 1 - 5 VDCᜡ /
DC
± 2 VDCᜡ
②
AC
0 - 20 VACᜠ / 0 - 5 VACᜠ / 0 - 2 VACᜠ
DC ± 500 VDCᜡ / ± 200 VDCᜡ / ± 50 VDCᜡ
③
0 - 500 VACᜠ / 0 - 200 VACᜠ /
AC
0 - 110 VACᜠ / 0 - 50 VACᜠ
■ Output
• 1: NPN open collector
1
2
3
OUT1
OUT2
COM
Specifications
Model
Input type
Max. allowable input
+DC input
-DC input
AC input
Display method
Display accuracy
23 ± 5 ℃ (DC input)
23 ± 5 ℃ (AC input)
0 to 50 ℃
Display cycle
Display scale
A / D conversion method ΣΔ (Sigma Delta) analog-to-digital converter
Power
Sampling cycle
(DC input)
8
9 10
Sampling cycle
(AC input)
Resolution
Preset output
Load voltage
Load current
Residual voltage
Unit weight (packaged) ≈ 77 g (≈ 100 g)
Approval
01) When using the unit at low temperature (below 0 ℃), display cycle is slow due to charateristics of LCD. Control
output operates normally.
02) 5 A terminal: ± 0.3 % F.S. rdg ± 3-digit
03) 5 A terminal: ± 1 % F.S. rdg ± 3-digit
Power supply
Power consumption
Insulation resistance
Dielectric strength
Noise immunity
Vibration
Vibration
(malfunction)
Shock
Shock (malfunction)
Ambient temperature
Ambient humidity
Insulation type
SOURCE
24 - 240 VACᜠ/ VDCᜡ
5
6
7
8
9
10
①
②
③
COM
MX4W-A-F□
± 20 mA / 4 - 20 mA / ± 5 mA / ± 2 mA
0 - 20 mA / 0 - 5 mA / 0 - 2 mA
± 500 mA / ± 200 mA / ± 50 mA
0 - 500 mA / 0 - 200 mA / 0 - 50 mA
± 5 A / ± 2 A
0 - 5 A / 0 - 2 A
• 2: PNP open collector
4
1
2
HOLD/
ZERO
OUT1
OUT2
MX4W-V-F□
DC / AC voltage
Dependent on the input type
≈ -10 to 110 % F.S. for each measured input range
≈ -110 to 110 % F.S. for each measured input range
≈ 110 % F.S. for each measured input range
12-segment LCD
01)
- measurement value display part: white, character height: 19 mm
- other display parts: red, green, yellow (indicator: white)
Dependent on the ambient temperature
± 0.1 % F.S. rdg ± 2-digit
± 0.3 % F.S. rdg ± 3-digit
± 0.5 % F.S. rdg ± 3-digit
0.2 to 5.0 sec (select per 0.1 sec)
-9999 to 9999 (4-digit)
50 ms
16.6 ms
1 / 20,000
NPN / PNP open collector output model
≤ 30 VDCᜡ
≤ 100 mA
NPN open collector output: ≤ 1 VDCᜡ /
PNP open collector output: ≤ 2 VDCᜡ
ᜢ ᜧ
24 - 240 VDCᜡ ± 10 %, 24 - 240 VACᜠ ± 10 % 50 / 60 Hz
DC: ≤ 3 W, AC: ≤ 5 VA
≥ 100 MΩ (500 VDCᜡ megger)
Between all terminals and case: 3,000 VACᜠ 50 / 60 Hz for 1 min
± 2 kV square wave noise (pulse width: 1 ㎲) by the noise simulator
0.75 mm double amplitude at frequency of 10 to 55 Hz (for 1
minute) in each X, Y, Z direction for 2 hours
0.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 minute)
in each X, Y, Z direction for 10 min
300 m/s
(≈ 30 G) in each X, Y, Z direction for 3 times
2
100 m/s
(≈ 10 G) in each X, Y, Z direction for 3 times
2
-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Symbol:
, double or reinforced insulation (dielectric strength
between the measurement input part and the power part: 1 kV)
3
4
HOLD/
COM
ZERO
MX4W-A-F□
DC / AC current
± 0.1 % F.S. rdg ± 2-digit
02)
± 0.3 % F.S. rdg ± 3-digit
± 0.5 % F.S. rdg ± 3-digit
03)