Autopilot APCETHD Посібник - Сторінка 11
Переглянути онлайн або завантажити pdf Посібник для Контролер Autopilot APCETHD. Autopilot APCETHD 18 сторінок.
Page 10
APCETHD
3) Select split (SPLit) if using a fan or AC unit as a cooling device
and a humidifier to add humidity. Each device is controlled
independently. The cooling device will turn on when the
temperature rises above the setting and the humidifier will turn on
when the humidity lowers below the setting.
Min/Maximum Temp - Press to "recall" or display the minimum
and maximum temperature recorded values. Each time the button
is pressed, the next setting will be displayed.
Min/Maximum Humidity - Press to "recall" or display the
minimum and maximum humidity recorded values. Each time the
button is pressed, the next setting will be displayed.
To reset the Min/Max values – When the recorded value is
displayed, press the Enter / Reset button and hold for 3 seconds.