Gas adjustments
Use pressure regulators that are suitable for the gas
pressure values indicated in the Product Description Sheet
supplied separately.
If the appliance is arranged for a type of gas different from that
available, it is necessary to change the injectors, adjust the
minimum flame, change the outlet connector.
Carry out the following operations to change the hob injectors:
remove the grills; remove the burners, the burner caps
(see Fig. 6); change the injector and replace it with one suitable
for the new type of gas (see table in separate Product Sheet).
Replace the gas calibration label with the new label included in the
injector bag.
Refit everything in reverse order, making sure to correctly fit the
burner cap on the burner.
Minimum for hob taps
To adjust the minimum flame, proceed as follows
• Light the burner and turn the knob to minimum
the tap knob (Fig. 7). Insert a small screwdriver next to the tap
pin (Fig. 8).
Turn the adjustment screw anticlockwise to increase the flame,
or clockwise to decrease it. Adjustment is correct when the flame
is approx. 3 - 4 mm.
The adjustment screw must be completely screwed down for
butane/propane gas.
Make sure the flame does not go out when switching suddenly
from high to low
flame
Refit the knob.
Room ventilation
Gas appliances
This appliance is not connected to a fume exhaust device.
Therefore it must be installed and connected in compliance with
current installation regulations.
Particular attention must be paid to the applicable standards
concerning room airing.
Room ventilation
This appliance can only be installed and used in well-ventilated
rooms, according to current regulations, with openings in the
walls or with special ducts enabling proper natural or forced
ventilation, thus ensuring permanent and adequate introduction
of air necessary for correct combustion and for extraction of
vitiated air.
In particular, if there is only this gas appliance in the room, a hood
must be installed above the appliance to ensure natural and direct
extraction of the vitiated air, with a straight vertical duct of length
equal to at least twice the diameter and a minimum section of at
2
least 100 cm
.
20
and vice versa.
; remove
Fig. 6
Fig. 7
Fig. 8